APPLICATION OF THE ARMA METHOD TO ACOUSTIC DETECTION OF CORONARY-ARTERY DISEASE

被引:32
作者
AKAY, M
WELKOWITZ, W
SEMMLOW, JL
KOSTIS, J
机构
[1] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT MED,PISCATAWAY,NJ 08854
[2] UNIV MED & DENT NEW JERSEY,ROBERT WOOD JOHNSON MED SCH,DEPT SURG BIOENGN,PISCATAWAY,NJ 08854
关键词
CORONARY ARTERY DISEASE; NONINVASIVE DETECTION; SOUND;
D O I
10.1007/BF02441656
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
To further explore the application of advanced signal processing techniques to the noninvasive detection of coronary artery disease, 30 patients (10 angioplasty and 20 normal or abnormal) were tested using autoregressive moving average (ARMA) modelling of the disastolic heart sound data. It is during diastole that coronary blood flow is maximum and sounds associated with turbulent blood flow through partially occluded coronary arteries would be loudest. Model parameters (the power spectral density (PSD) functions and the poles of the ARMA method) were used to separate the normal patients from the abnormal patients in the normal/abnormal study, or to decide whether the recordings were made before or after angioplasty in the angioplasty study. The decisions were made 'blind', without knowledge of the actual disease states of the patients for the normal/abnormal study and without prior knowledge of whether a given recording was made before or after angioplasty for the angioplasty study. Results from the angioplasty and the normal/abnormal studies showed that pre- and post-angioplasty records were correctly distinguished in 8 out of 10 cases, and normal and abnormal records were correctly distinguished in 17 of 20 cases. These results also confirmed that high frequency energy above 400 Hz is probably associated with coronary stenosis.
引用
收藏
页码:365 / 372
页数:8
相关论文
共 26 条
  • [1] NONINVASIVE DETECTION OF CORONARY STENOSES BEFORE AND AFTER ANGIOPLASTY USING EIGENVECTOR METHODS
    AKAY, M
    SEMMLOW, JL
    WELKOWITZ, W
    BAUER, MD
    KOSTIS, JB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (11) : 1095 - 1104
  • [2] DETECTION OF CORONARY OCCLUSIONS USING AUTOREGRESSIVE MODELING OF DIASTOLIC HEART SOUNDS
    AKAY, M
    SEMMLOW, JL
    WELKOWITZ, W
    BAUER, MD
    KOSTIS, JB
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1990, 37 (04) : 366 - 373
  • [3] AKAY M, 1990, THESIS RUTGERS U PIS
  • [4] AKAY M, 1988, P IEEE FRONTIERS MED, P72
  • [5] AKAY M, 1989, P IEEE FRONTIERS MED, P51
  • [6] BOX G, 1970, J AM STAT ASSOC, V64, P122
  • [7] INFORMATION TRADEOFFS IN USING THE SAMPLE AUTO-CORRELATION FUNCTION IN ARMA PARAMETER-ESTIMATION
    BRUZZONE, SP
    KAVEH, M
    [J]. IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1984, 32 (04): : 701 - 715
  • [8] DIASTOLIC MURMUR CAUSED BY CORONARY ARTERY STENOSIS
    CHENG, TO
    [J]. ANNALS OF INTERNAL MEDICINE, 1970, 72 (04) : 543 - +
  • [9] A DIASTOLIC MURMUR ARISING IN A STENOSED CORONARY ARTERY
    DOCK, W
    ZONERAICH, S
    [J]. AMERICAN JOURNAL OF MEDICINE, 1967, 42 (04) : 617 - +
  • [10] DUNCAN GW, 1975, NEW ENGL J MED, V27, P1124