EARLY ACCIDENTAL DISLODGMENT OF PEG TUBES

被引:33
作者
MARSHALL, JB
BODNARCHUK, G
BARTHEL, JS
机构
[1] Division of Gastroenterology, University of Missouri School of Medicine, Columbia, MO
关键词
PEG TUBES; DISLODGMENT; GASTROSTOMY TUBES; ENTERAL NUTRITION;
D O I
10.1097/00004836-199404000-00007
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Newer percutaneous endoscopy gastrostomy (PEG) tubes with soft internal bolsters may be prone to accidental dislodgement or removal by patients. When this occurs after a mature gastrocutaneous fistula has formed, it is of little consequence as long as a replacement tube is promptly reinserted before the track closes. Blind reinsertion of a replacement tube before the track is adequately mature may have serious consequences, as exemplified by a patient who developed peritonitis as a result of inadvertent insertion into the peritoneal cavity. We managed two other patients with early accidental PEG tube removal by a period of nasogastric (NG) suction, intravenous antibiotic drugs, and observation, with a new tube placed endoscopically 7-9 days later. We review the management of early, inadvertent dislodgement of PEG tubes.
引用
收藏
页码:210 / 212
页数:3
相关论文
共 9 条