EFFECTS OF ATRIAL, VENTRICULAR, AND ATRIOVENTRICULAR SEQUENTIAL PACING ON CORONARY FLOW RESERVE

被引:21
作者
KOLETTIS, TM
KREMASTINOS, DT
KYRIAKIDES, ZS
TSIRAKOS, A
TOUTOUZAS, PK
机构
[1] ATHENS GEN HOSP, DEPT CARDIOL, ATHENS, GREECE
[2] HIPPOKRATEION HOSP, DEPT CARDIOL, ATHENS, GREECE
来源
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY | 1995年 / 18卷 / 09期
关键词
PACING; CORONARY FLOW RESERVE;
D O I
10.1111/j.1540-8159.1995.tb06984.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Experimental animal data have indicated that altered left ventricular depolarization sequence as a result of right ventricular pacing may diminish coronary blood flow in the distribution of the left anterior descending coronary artery. To further investigate this, we compared the effects of atrial, ventricular, curd atrioventricular (AV) sequential pacing on coronary flow reserve. Twenty-seven patients (24 male, mean age 55 +/- 7 years) with normal left anterior descending coronary arteries were studied. Coronary flow reserve was calculated as the ratio of mean flow velocity at maximal coronary vasodilatation to mean flow velocity at baseline. The study consisted of two parts. In the first part, AV sequential pacing was compared to atrial pacing at the same rate; coronary flow reserve did not differ significantly between the two pacing modes (14 patients, 4.85 +/- 1.88 vs 5.47 +/- 1.55, respectively, P > 0.05). In the second part, all three pacing modalities were compared; coronary flow reserve was significantly higher during ventricular compared to AV sequential pacing, but not significantly different compared to atrial pacing (3.69 +/- 1.42 vs 2.90 +/- 0.86 vs 3.11 +/- 0.89, respectively, P < 0.05). This difference was secondary to a significant decrease in mean baseline velocity during ventricular pacing, while mean velocity during hyperemia was comparable between the three pacing modes. It is concluded that AV sequential pacing does not appear to exert a significant effect on coronary flow reserve. Ventricular pacing, however, may lower resting coronary blood velocity in some patients, without affecting maximal coronary blood velocity, resulting in a higher coronary flow reserve.
引用
收藏
页码:1628 / 1635
页数:8
相关论文
共 27 条
[1]  
Hirzel HO, Senn M, Nuesch K, Et al., Thallium‐201 scintigraphy in complete left bundle branch block, Am J Cardiol, 53, pp. 764-769, (1984)
[2]  
Vrobel TR, Ring WS, Anderson RW, Et al., Effect of heart rate on myocardial blood flow in dogs with left ventricular hypertrophy, Am J Physiol, 239, (1980)
[3]  
Ono S, Nohara R, Kambara H, Et al., Regional myocardial perfusion and glucose metabolism in experimental left bundle branch block, Circulation, 85, pp. 1125-1131, (1992)
[4]  
Braat SH, Brugada P, Bar FW, Et al., Thallium‐201 exercise scintigraphy and left bundle branch block, Am J Cardiol, 55, pp. 224-226, (1985)
[5]  
Huerta EM, Rodriguez PL, Castro Beiras JM, Et al., Thallium‐201 exercise scintigraphy in patients having complete left bundle branch block with normal coronary arteries, Int J Cardiol, 16, pp. 43-46, (1987)
[6]  
DePuey EG, Guertler-Krawczynska E, Robbins W, Thallium‐201 SPECT in coronary artery disease patients with left bundle branch block, J Nucl Med, 29, pp. 1479-1485, (1988)
[7]  
Feigl EO, Coronary physiology, Phys Rev, 63, pp. 1-205, (1983)
[8]  
Kern MJ, Intracoronary flow velocity: Current techniques and clinical applications of Doppler catheter methods, Intravascular Ultrasound Imaging, pp. 93-111, (1992)
[9]  
Kyriakides ZS, Kremastinos DT, Kolettis TM, Et al., Short‐term effects of atrial versus atrio‐ventricular pacing on myocardial ischaemia in coronary artery disease patients, Eur Heart J, 14, pp. 607-613, (1993)
[10]  
Segal J, Kern MJ, Scott NA, Et al., Alterations of phasic coronary artery flow velocity in humans during percutaneous coronary angioplasty, Journal of the American College of Cardiology, 20, pp. 276-286, (1992)