ENHANCED SELECTIVITY IN ION MOBILITY SPECTROMETRY ANALYSIS OF COMPLEX-MIXTURES BY ALTERNATE REAGENT GAS CHEMISTRY

被引:60
作者
EICEMAN, GA
WANG, YF
GARCIAGONZALEZ, L
HARDEN, CS
SHOFF, DB
机构
[1] USA,EDGEWOOD RES & DEV ENGN CTR,RES & TECHNOL DIRECTORATE,ABERDEEN PROVING GROUND,MD 21010
[2] NEW MEXICO STATE UNIV,DEPT CHEM,LAS CRUCES,NM 88003
关键词
MASS SPECTROMETRY; VOLATILE ORGANIC COMPOUNDS; ORGANOPHOSPHORUS COMPOUNDS;
D O I
10.1016/0003-2670(94)00668-C
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Ion mobility spectrometry (IMS) analysis of a complex mixture of volatile organic compounds (VOCs) and organophosphorus compounds (OPCs) at vapor levels of 10-40 mg/m(3) produced mobility spectra with broad profiles illustrating limitations of ion mobility spectrometry (IMS) for screening such mixtures. Preseparation of this mixture with a gas chromatograph inlet to an ion mobility spectrometer enhanced analytical selectivity although OPC detection was complicated by co-elution with other VOCs. Water reagent gas in the ion source of the ion mobility spectrometer yielded 46 gas chromatographic peaks in a mixture of 45 VOCs and 19 OPCs. Co-elution of two materials was observed in eight of the chromatographic peaks and co-elution of three materials occurred in four instances. Further selectivity was gained using reagent gases of elevated proton affinity in the ion source. Reagent gas chemistry for acetone and dimethylsulfoxide reduced the number of GC peaks to 26 and 20, respectively. Moreover, spectral integrity and quantitative response for OPCs were retained at 50 to 1000 pg levels with these reagent gases. For OPCs, analyte ions were shown to be of the type M(2)H(+) under these conditions of analysis and the mobilities of the product ions were independent of reagent gas. Reduced mobility values were assigned to OPC spectra using a well-characterized OPC ion as the reference. Spectral profiles and reduced mobilities suggested that the OPC product ions were not clustered with reagent gas molecules at 100 degrees C.
引用
收藏
页码:21 / 33
页数:13
相关论文
共 24 条
[1]  
Eiceman, Advances in Ion Mobility Spectrometry: 1980–1990, Critical Reviews in Analytical Chemistry, 22, (1991)
[2]  
Karasek, Keller, Gas Chromatograph/Plasma Chromatograph Interface and Its Performance in the Detection of Musk Ambrette, Journal of Chromatographic Science, 10, (1972)
[3]  
Cram, Chester, Coupling of High Speed Plasma Chromatography With Gas Chromatography, Journal of Chromatographic Science, 11, (1973)
[4]  
Boggs, Tou, Determination of sub parts-per-million levels of sec-butyl chlorodiphenyl oxides in biological tissues by plasma chromatography, Analytical Chemistry, 48, (1976)
[5]  
Karasek, Hill, Kim, Rokushika, J. Chromatogr., 135, (1977)
[6]  
Baim, Hill, Tunable selective detection for capillary gas chromatography by ion mobility monitoring, Analytical Chemistry, 54, (1982)
[7]  
Snyder, Harden, Brittain, Kim, Arnold, Meuzelaar, Anal. Chem., 65, (1993)
[8]  
Brokenshire, Cummings, Overton, Carney, Limero, Cross, James, Eiceman, A Volatile Organic Analyzer for Space Station: Description and Evaluation of Gas Chromatography/Ion Mobility Spectrometry, Proceedings from the 22nd International Conference on Environmental Systems, (1992)
[9]  
Baim, Hill, J. Chromatogr., 279, (1983)
[10]  
Louis, Hill, Electron capture ion mobility spectrometry for the selective detection of chlorinated and brominated species after capillary gas chromatography, Journal of High Resolution Chromatography, 13, (1990)