THE DETERMINATION OF SUB PART-PER-BILLION LEVELS OF VOLATILE ORGANIC-COMPOUNDS IN AIR BY PRECONCENTRATION FROM SMALL SAMPLE VOLUMES

被引:7
作者
ALMASI, E [1 ]
KIRSHEN, N [1 ]
KERN, H [1 ]
机构
[1] VARIAN INT AG,CH-6303 ZUG,SWITZERLAND
关键词
CRYOGENIC CONCENTRATOR; ION TRAP GC-MS; FULL SCAN SPECTRA; AIR; VOLATILE ORGANIC COMPOUNDS;
D O I
10.1080/03067319308042846
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Trace level Volatile Organic Compounds (VOCs) in ambient air are normally determined according to EPA Method TO-14. This method describes the analysis in ambient air of 41 VOCs, ranging in boiling point from -29 to 215-degrees-C. It covers a concentration range from 0.2 to 20 parts per billion, volume/volume (ppb), and specifies sample enrichment of a 400 mL air sample on glass beads at -160-degrees-C. While this sample volume provides sub-ppb levels of VOC detection for target analytes when using a quadrupole mass spectrometer detector in SIM mode or when using GC detectors, the identification of non-target analytes may only be done in full scan mode for higher concentrations. Also with this sample volume a Nafion dryer is needed for water removal thereby lowering the recovery of polar VOCs. Because of the very high sensitivity of the ion trap MS, relatively small air volumes (60 mL) are adequate to obtain the required or lower detection levels. An integrated air analysis system based on a GC-ion-trap MS has been investigated and is described. This system has a built-in cryogenic trap and necessary valving, internal standard gas sampling loop, and is controlled from the GC-MS workstation. The linearity, precision, and method detection levels obtainable with this system when using small volumes are reported. In addition, examples of the quantitative and qualitative analysis of ambient air samples are shown.
引用
收藏
页码:39 / 48
页数:10
相关论文
共 9 条
[1]  
ALMASI E, 1989, VARIAN GC APPLICATIO, V19
[2]  
ALMASI E, 1990, VARIAN GC APPLICATIO, V32
[3]  
HOLDREN MW, 1983, STABILITY VOLATILE O
[4]  
MCCLENNY WA, 1991, J AIR WASTE MANAGE, V41, P1308
[5]   AUTOMATED CRYOGENIC PRECONCENTRATION AND GAS-CHROMATOGRAPHIC DETERMINATION OF VOLATILE ORGANIC-COMPOUNDS IN AIR [J].
MCCLENNY, WA ;
PLEIL, JD ;
HOLDREN, MW ;
SMITH, RN .
ANALYTICAL CHEMISTRY, 1984, 56 (14) :2947-2951
[6]   SAMPLE INTEGRITY OF TRACE LEVEL VOLATILE ORGANIC-COMPOUNDS IN AMBIENT AIR STORED IN SUMMA POLISHED CANISTERS [J].
OLIVER, KD ;
PLEIL, JD ;
MCCLENNY, WA .
ATMOSPHERIC ENVIRONMENT, 1986, 20 (07) :1403-1411
[7]   THE USE OF AUTOMATED ON LINE GAS-CHROMATOGRAPHY FOR THE MONITORING OF ORGANIC TRACE GASES IN THE ATMOSPHERE AT LOW-LEVELS [J].
RUDOLPH, J ;
JOHNEN, FJ ;
KHEDIM, A ;
PILWAT, G .
INTERNATIONAL JOURNAL OF ENVIRONMENTAL ANALYTICAL CHEMISTRY, 1990, 38 (02) :143-155
[8]  
1991, AIR COLLECTED CAN 1A, pCH1
[9]  
1988, TO14 US ENV PROT AG