EVALUATION OF A PACS WORKSTATION FOR ASSESSMENT OF BODY CT STUDIES

被引:13
作者
BERBAUM, KS
FRANKEN, EA
HONDA, H
MCGUIRE, C
WEIS, RR
BARLOON, T
机构
[1] Department of Radiology, University of Iowa, Iowa City, IA
[2] Department of Radiology, Kyushu University Faculty of Medicine, Fukuoka
[3] Wichita, KS
[4] Carondelet Radiology Inc, Kansas City, MO
关键词
Apparatus and Equipment; Computed tomography; Performance evaluation; Techniques;
D O I
10.1097/00004728-199009000-00042
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Conventional hardcopy images from 266 body CT studies were compared with those provided at a commercially available picture archiving communication system (PACS) workstation. Unprocessed PACS images were larger but otherwise precisely duplicated hardcopy images. The PACS images were evaluated before and after application of various image processing/ display features. Approximately three-quarters of the cases were depicted equally well with PACS and hardcopy, but in one quarter of the cases, diagnostic features were judged to be shown more clearly at the PACS workstation. When PACS images were viewed first, change in diagnosis after subsequent hardcopy inspection was infrequent (confidence change: 4%; different findings: 2%). Conversely, when hardcopy images were viewed first, change in diagnosis after subsequent PACS inspection was more frequent (confidence change: 19%; different findings: 8%). Specialized image manipulation available on PACS was critical for its performance. Review of cases with new findings discovered during the second inspection showed the majority of them to be clinically significant, true-positives discovered by PACS. We conclude that PACS is a useful modality for interpretation of body CT images. © 1988 Raven Press, Ltd., New York.
引用
收藏
页码:853 / 858
页数:6
相关论文
共 24 条
[1]  
BRUNING JL, 1977, COMPUTATIONAL HDB ST, P222
[2]  
Burgess A. E., 1986, Proceedings of the SPIE - The International Society for Optical Engineering, V626, P208, DOI 10.1117/12.975395
[3]   FINDING LUNG NODULES WITH AND WITHOUT COMPARATIVE VISUAL SCANNING [J].
CARMODY, DP ;
NODINE, CF ;
KUNDEL, HL .
PERCEPTION & PSYCHOPHYSICS, 1981, 29 (06) :594-598
[4]  
Fechner G. T., 1860, ELEMENT PSYCHOPHYSIK
[5]  
FRANKEN EA, 1990, IN PRESS CARDIAC IMA
[6]   DIGITAL IMAGING OF THE CHEST [J].
FRASER, RG ;
SANDERS, C ;
BARNES, GT ;
MACMAHON, H ;
GIGER, ML ;
DOI, K ;
TEMPLETON, AW ;
COX, GG ;
DWYER, SJ ;
MERRITT, CRB ;
JONES, JP .
RADIOLOGY, 1989, 171 (02) :297-307
[7]  
GESCHEIDER GA, 1985, PSYCHOPHYSICS METHOD, P135
[8]  
GOODENOUGH DJ, 1976, MED IMAGES FORMATION, P263
[9]   PERCEPTIBILITY OF EXPERIMENTAL AND CLINICAL LESIONS IN THE CT IMAGE WITH AND WITHOUT IMAGE-PROCESSING [J].
HEMMINGSSON, A ;
JUNG, B ;
NASLUND, L ;
YTTERBERGH, C .
ACTA RADIOLOGICA-DIAGNOSIS, 1981, 22 (01) :67-76
[10]   DIGITAL IMAGE-PROCESSING - EFFECT ON DETECTABILITY OF SIMULATED LOW-CONTRAST RADIOGRAPHIC PATTERNS [J].
ISHIDA, M ;
DOI, K ;
LOO, LN ;
METZ, CE ;
LEHR, JL .
RADIOLOGY, 1984, 150 (02) :569-575