ON THE DOPPLER SIGNAL FROM A STEADY FLOW ASYMMETRICAL STENOSIS MODEL - EFFECTS OF TURBULENCE

被引:28
作者
BASCOM, PAJ
COBBOLD, RSC
ROUTH, HF
JOHNSTON, KW
机构
[1] UNIV TORONTO, INST BIOMED ENGN, TORONTO M5S 1A4, ONTARIO, CANADA
[2] ADV TECHNOL LABS, BOTHELL, WA 98041 USA
基金
加拿大自然科学与工程研究理事会;
关键词
DOPPLER ULTRASOUND; TURBULENCE; SIGNAL STATISTICS; DOPPLER INDEXES; DECORRELATION TIME; HEMATOCRIT;
D O I
10.1016/0301-5629(93)90110-A
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
A steady flow model with a 70% (by area) asymmetrical stenosis was used to examine how changing flow regimes (laminar to turbulent) affect the Doppler signal. Human red blood cells (RBCs) (Hct = 42%) in saline were employed at a flow rate corresponding to a Reynold's number of approximately 545. A dilute suspension of 4% fixed RBCs was also used for the purpose of backscattered power comparison. Measurements of the Doppler signal enabled the backscattered power, time domain statistics, frequency spectra, frequency domain statistics, various spectral indices, autocorrelation function and decorrelation time to be calculated as a function of distance from the stenosis. It is shown that the characteristics of the Doppler signal measured at each site provide information on the nature of the insonated flow field and these correlate well with those expected. The results demonstrate that the onset of turbulence not only affects the Doppler spectrum but also has a profound effect on the signal power, the decorrelation time and the signal statistics.
引用
收藏
页码:197 / 210
页数:14
相关论文
共 30 条
[1]   DIAGNOSIS OF URETHRAL FLOW PARAMETERS BY ULTRASONIC BACKSCATTER [J].
ALBRIGHT, RJ ;
HARRIS, JH .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1975, BM22 (01) :1-11
[2]   THEORETICAL-STUDY OF THE SCATTERING OF ULTRASOUND FROM BLOOD [J].
ANGELSEN, BAJ .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1980, 27 (02) :61-67
[3]  
AZUMA T, 1976, BIORHEOLOGY, V13, P337
[4]  
Bascom P. A. J., 1988, IEEE 1988 Ultrasonics Symposium. Proceedings (IEEE Cat. No.88CH2578-3), P985, DOI 10.1109/ULTSYM.1988.49524
[5]   EFFECTS OF TRANSDUCER BEAM GEOMETRY AND FLOW VELOCITY PROFILE ON THE DOPPLER POWER SPECTRUM - A THEORETICAL-STUDY [J].
BASCOM, PAJ ;
COBBOLD, RSC .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1990, 16 (03) :279-295
[6]  
BASCOM PAJ, 1990, IEEE EMBS C P PHIL N, P557
[7]  
BASCOM PAJ, 1988, THESIS U TORONTO
[8]   VARIATION OF DOPPLER ULTRASOUND SPECTRAL WIDTH IN THE POST-STENOTIC VELOCITY-FIELD [J].
CAMPBELL, JD ;
HUTCHISON, KJ ;
KARPINSKI, E .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1989, 15 (07) :611-619
[9]   CYCLIC CHANGES OF BLOOD ECHOGENICITY IN HIGH-FREQUENCY ULTRASOUND [J].
DEKROON, MGM ;
SLAGER, CJ ;
GUSSENHOVEN, WJ ;
SERRUYS, PW ;
ROELANDT, JRTC ;
BOM, N .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1991, 17 (07) :723-728
[10]   AN INVITRO MODEL AND ITS APPLICATION FOR THE STUDY OF CAROTID DOPPLER SPECTRAL BROADENING [J].
DOUVILLE, Y ;
JOHNSTON, KW ;
KASSAM, M ;
ZUECH, P ;
COBBOLD, RSC ;
JARES, A .
ULTRASOUND IN MEDICINE AND BIOLOGY, 1983, 9 (04) :347-356