摘要
New reactive azo dyes are described which are useful for optical determination of pH. The dyes are covalently linked (via ethylsulfonyl groups) to a novel type of transparent solid films consisting of a thin film of cellulose on top of a polyester support. The resulting membranes exhibit distinct color change when changing the pH and, in most cases, are compatible with LED light sources. Various membranes have been developed with pK(a) values ranging from 0.5 to 11.28, thus practically covering the whole pH range. Because of the stability of the dyes, the covalent bond and the solid support, the new membranes exhibit storage stability over years, and operational lifetimes of weeks, good reproducibility and a fast (30-60 s) response to pH.
引用
收藏
页码:41 / 48
页数:8
相关论文
共 20 条
[1]   SPECTROPHOTOMETRIC INVESTIGATIONS ON IMMOBILIZED ACID-BASE INDICATORS [J].
BACCI, M ;
BALDINI, F ;
SCHEGGI, AM .
ANALYTICA CHIMICA ACTA, 1988, 207 (1-2) :343-348
[2]   SYNTHESIS AND CHARACTERIZATION OF NEUTRAL HYDROGEN ION-SELECTIVE CHROMOIONOPHORES FOR USE IN BULK OPTODES [J].
BAKKER, E ;
LERCHI, M ;
ROSATZIN, T ;
RUSTERHOLZ, B ;
SIMON, W .
ANALYTICA CHIMICA ACTA, 1993, 278 (02) :211-225
[3]  
BRANDRUP J, 1989, POLYM HDB, P437
[4]   SYNTHESIS OF CELLULOSE-EXCHANGERS WITH CHELATE-FORMING FUNCTIONAL-GROUPS [J].
BURBA, P ;
LIESER, KH .
ANGEWANDTE MAKROMOLEKULARE CHEMIE, 1976, 50 (FEB) :151-161
[5]   DETERMINATION OF PH WITH ACID-BASE INDICATORS - IMPLICATIONS FOR OPTICAL FIBER PROBES [J].
EDMONDS, TE ;
FLATTERS, NJ ;
JONES, CF ;
MILLER, JN .
TALANTA, 1988, 35 (02) :103-107
[6]   EXPERIMENTAL RESULTS ON AN OPTICAL PH MEASUREMENT SYSTEM FOR BIOREACTORS [J].
HOLOBAR, A ;
WEIGL, BH ;
TRETTNAK, W ;
BENES, R ;
LEHMANN, H ;
RODRIGUEZ, NV ;
WOLLSCHLAGER, A ;
OLEARY, P ;
RASPOR, P ;
WOLFBEIS, OS .
SENSORS AND ACTUATORS B-CHEMICAL, 1993, 11 (1-3) :425-430
[7]  
HOLOBAR A, UNPUB ANAL METHODS I
[8]   DO OPTICAL SENSORS REALLY MEASURE PH [J].
JANATA, J .
ANALYTICAL CHEMISTRY, 1987, 59 (09) :1351-1356
[9]   OPTICAL PH SENSOR BASED ON THE CHEMICAL MODIFICATION OF A POROUS POLYMER FILM [J].
JONES, TP ;
PORTER, MD .
ANALYTICAL CHEMISTRY, 1988, 60 (05) :404-406
[10]   STUDIES WITH IMMOBILIZED CHEMICAL REAGENTS USING A FLOW-CELL FOR THE DEVELOPMENT OF CHEMICALLY SENSITIVE FIBRE-OPTIC DEVICES [J].
KIRKBRIGHT, GF ;
NARAYANASWAMY, R ;
WELTI, NA .
ANALYST, 1984, 109 (01) :15-17