IN-VIVO PH MEASUREMENT AND IMAGING OF TUMOR-TISSUE USING A PH-SENSITIVE FLUORESCENT-PROBE (5,6-CARBOXYFLUORESCEIN) - INSTRUMENTAL AND EXPERIMENTAL STUDIES

被引:61
作者
MORDON, S
DEVOISSELLE, JM
MAUNOURY, V
机构
[1] UNIV MONTPELLIER 1, FAC PHARM, TECH PHARMACEUT IND LAB, F-34060 MONTPELLIER, FRANCE
[2] CTR HOSP REG & UNIV LILLE, CTR MULTIDISCIPLINARY TRAITEMENT LASER, F-59037 LILLE, FRANCE
关键词
D O I
10.1111/j.1751-1097.1994.tb05104.x
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study evaluated the effectiveness of dual-wavelength ratio fluorescence imaging using a pH-dependent indicator (5,6-carboxyfluorescein, 5,6-CF) for in vivo pH mapping of tissue. A prototype version of a highly sensitive fluorescence imaging device consisting of a modified xenon lamp, an image-intensified camera and a digital image-processing system has been developed. 5,6-Carboxyfluorescein was used because its fluorescence emission increases as a function of pH in the physiological (6.0-7.4) pH range. The ratio of fluorescence intensities obtained with the imaging system has been calibrated using aqueous 5,6-CF standards at various pH values. Because the pH of interstitial fluid of malignant tumors tends to be lower than that of normal tissue and can be depressed by glucose administration, experiments were performed on 10 CDF mice bearing lymphoid leukemia P388 grafted subcutaneously. The range of linearity of the calibration curve was obtained between 5.3 and 6.7 with a measured pK(a) value of 5.93. Consequently the maximum sensitivity was observed in this range. The calculated pH from ratio images was 6.21 +/- 0.12 in tumorous tissue. This value was equivalent to those obtained at the same time using microelectrodes (6.2 +/- 0.3). These experiments showed that a dose of 5 mg/kg 5,6-CF and an excitation power density of 2.5 mW/cm(2) are sufficient to give a fluorescent pH image of tumors. The limitation of 5,6-CF for the in vivo mapping of tissue results from its low pK(a) and consequent range of sensitivity. The advantages of this imaging technique compared to microelectrodes are that it (1) is noninvasive, (2) displays a two-dimensional pH image with high resolution (profile distribution of pH in tissue) and (3) can be used to monitor pH over a few hours.
引用
收藏
页码:274 / 279
页数:6
相关论文
共 24 条
  • [1] ASHBY SS, 1966, LANCET 0806, P312
  • [2] BABCOCK DF, 1983, J BIOL CHEM, V258, P6380
  • [3] BONANNO JA, 1987, INVEST OPHTH VIS SCI, V28, P522
  • [4] MEASUREMENT OF INVIVO TUMOROUS NORMAL TISSUE PH BY LOCALIZED SPECTROSCOPY USING A FLUORESCENT MARKER
    DEVOISSELLE, JM
    MAUNOURY, V
    MORDON, S
    COUSTAUT, D
    [J]. OPTICAL ENGINEERING, 1993, 32 (02) : 239 - 243
  • [5] GILLES RJ, 1982, INTRACELLULAR PH ITS, P21
  • [6] CHARACTERISTICS OF FLUOROPROBES FOR MEASURING INTRACELLULAR PH
    GRABER, ML
    DILILLO, DC
    FRIEDMAN, BL
    PASTORIZAMUNOZ, E
    [J]. ANALYTICAL BIOCHEMISTRY, 1986, 156 (01) : 202 - 212
  • [7] COMPARISON OF PH MEASUREMENTS MADE USING P-31 NMR AND A FIBEROPTIC PH-METER
    JAYASUNDAR, R
    HALL, LD
    BLEEHEN, NM
    [J]. NMR IN BIOMEDICINE, 1992, 5 (06) : 360 - 363
  • [8] KHOOBEHI B, 1990, OPHTHALMOLOGY, V97, P1061
  • [10] PH-DEPENDENCE OF FLUORESCEIN FLUORESCENCE
    MARTIN, MM
    LINDQVIST, L
    [J]. JOURNAL OF LUMINESCENCE, 1975, 10 (06) : 381 - 390