AN AUTOMATED TACTILE TESTER FOR EVALUATION OF CUTANEOUS SENSIBILITY

被引:25
作者
HORCH, K
HARDY, M
JIMENEZ, S
JABALEY, M
机构
[1] St. Dominic Hand Center, Jackson, MS
来源
JOURNAL OF HAND SURGERY-AMERICAN VOLUME | 1992年 / 17A卷 / 05期
基金
美国国家卫生研究院;
关键词
D O I
10.1016/0363-5023(92)90452-U
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The Automated Tactile Tester (ATT) is a computer-controlled device designed to measure patients' cutaneous perception of touch, vibration, temperature, and pain. The ATT provides repeatable and precise control of the amplitude, rate of application, and duration of stimuli. Threshold values for skin indentation (touch), high- and low-frequency vibration, pinprick (sharpness), warmth, and two-point discrimination were obtained with the ATT from the fingers of 62 normal subjects. Manual monofilament and two-point discrimination tests were also performed on the same subjects. All the tests with the ATT, except pinprick, showed a statistically significant increase in threshold with age. There were no significant differences attributable to the hand or digit tested or the sex of the subject. These data were used to derive age-adjusted criteria for normal sensory function in the glabrous skin of the lingers. Thresholds were found to remain within normal limits when these subjects were retested at various time intervals. We conclude that the ATT provides repeatable and reliable measurements of sensory function in the skin and has potential application in the diagnosis and evaluation of compression and other peripheral neuropathies.
引用
收藏
页码:829 / 837
页数:9
相关论文
共 27 条
[1]
Fruhstorfer, Lindblom, Sensibility abnormalities in neuralgic patients studied by thermal and tactile pulse stimulation, Somatosensory mechanisms, (1984)
[2]
Dyck, Quantitation of cutaneous sensation in man, Peripheral neuropathy, (1975)
[3]
Dyck, Schultz, O'Brien, Quantitation of touch-pressure sensation, Arch Neurol, 26, pp. 465-473, (1972)
[4]
Dyck, Curtis, Bushek, Offord, Description of “Minnesota thermal disks” and normal values of cutaneous thermal discrimination in man, Neurology, 24, pp. 325-330, (1974)
[5]
Dyck, O'Brien, Bushek, Oviatt, Schilling, Stevens, Clinical vs. quantitative evaluation of cutaneous sensation, Arch Neurol, 33, pp. 651-655, (1976)
[6]
Dyck, Zimmerman, O'Brien, Et al., Introduction of automated systems to evaluate touch-pressure, vibration and thermal cutaneous sensation in man, Ann Neurol, 4, pp. 502-510, (1978)
[7]
Potvin, Tourtellotte, Scientific basis and design of instrumented tests, Quantitative examination of neurologic functions, (1985)
[8]
Feldman, Neurology: the physician's guide, (1984)
[9]
Jewett, McCarroll, Nerve repair and regeneration: its clinical and experimental basis, (1980)
[10]
Schmidt, Thews, Human physiology, (1983)