A parametric investigation of an electrospray ion source and interface has been carried out with a focus on elemental analysis. The source and interface variables investigated were the curtain-gas flow rate and the voltage biases of the electrospray capillary tip, the front plate, the sampling plate, the skimmer, and the barrel ion extractor lens. The analytes studied (M(+) and M(++)) included the alkali metals, the alkaline earth metals, and cobalt-all prepared in methanol (MeOH) solutions. The two most important interface parameters in terms of their effect on the nature of the resulting mass spectrum were the curtain-pas flow rate and the sampling-plate voltage bias. A minimum, but modest, flow rate of curtain gas was required in order to observe analyte ion signals, and, when combined with a low sampling-plate voltage, the observed signal species were primarily analyte ion-solvent clusters [M(MeOH)(n)(+1) and M(MeOH)(n)(+2)]. As the values of these two parameters were increased, these species were declustered, plus-two analyte ions were reduced to plus-one species, and ultimately the mass spectra were dominated by the bare singly charged analyte ion (M(+)). Also, these two variables (curtain-gas Bow rate and sampling-plate voltage) seem to act in a synergistic manner, with neither variable alone able to effect complete declustering and charge reduction.
引用
收藏
页码:324 / 334
页数:11
相关论文
共 24 条
[1]   ELEMENTAL SPECIATION MEASUREMENTS WITH ELECTROSPRAY MASS-SPECTROMETRY - AN ASSESSMENT [J].
AGNES, GR ;
STEWART, II ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (11) :1347-1359
[2]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - PRELIMINARY-RESULTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1992, 46 (03) :401-406
[3]   DETERMINATION OF SOLUTION IONS BY ELECTROSPRAY MASS-SPECTROMETRY [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :655-661
[4]   ELECTROSPRAY MASS-SPECTROMETRY AS A TECHNIQUE FOR ELEMENTAL ANALYSIS - QUANTITATIVE ASPECTS [J].
AGNES, GR ;
HORLICK, G .
APPLIED SPECTROSCOPY, 1994, 48 (06) :649-654
[5]   1ST STUDIES OF THE GAS-PHASE ION CHEMISTRY OF M3+ METAL-ION LIGANDS [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 101 (2-3) :325-336
[6]   STUDIES OF ALKALINE-EARTH AND TRANSITION-METAL M++ GAS-PHASE ION CHEMISTRY [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
JOURNAL OF CHEMICAL PHYSICS, 1990, 92 (10) :5900-5906
[7]   ION-MOLECULE CLUSTERS INVOLVING DOUBLY CHARGED METAL-IONS (M2+) [J].
BLADES, AT ;
JAYAWEERA, P ;
IKONOMOU, MG ;
KEBARLE, P .
INTERNATIONAL JOURNAL OF MASS SPECTROMETRY AND ION PROCESSES, 1990, 102 :251-267
[8]   MOLECULAR BEAMS OF MACROIONS [J].
DOLE, M ;
MACK, LL ;
HINES, RL .
JOURNAL OF CHEMICAL PHYSICS, 1968, 49 (05) :2240-&
[9]   ION FORMATION FROM CHARGED DROPLETS - ROLES OF GEOMETRY, ENERGY, AND TIME [J].
FENN, JB .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :524-535
[10]   ELECTROSPRAY ION SPRAY - A COMPARISON OF MECHANISMS AND PERFORMANCE [J].
IKONOMOU, MG ;
BLADES, AT ;
KEBARLE, P .
ANALYTICAL CHEMISTRY, 1991, 63 (18) :1989-1998