ECG-OPTIMIZED PHASE-CONTRAST LINE-SCANNED MR ANGIOGRAPHY

被引:14
作者
KOROSEC, FR [1 ]
MISTRETTA, CA [1 ]
TURSKI, PA [1 ]
机构
[1] UNIV WISCONSIN, DEPT RADIOL, MADISON, WI 53792 USA
关键词
D O I
10.1002/mrm.1910240204
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We describe a rapid phase contrast line scan MR angiographic imaging technique. A projection angiogram is obtained by sequentially imaging a series of thin slices oriented perpendicular to the primary flow direction. Bipolar gradient subtraction is employed to suppress signal from static tissues, which in turn allows elimination of phase encoding in the depth dimension. The sequence is cardiac gated to improve image quality and to allow observation of hemodynamics. To further improve image quality, the amplitude of the bipolar gradient is altered throughout the cardiac cycle to provide maximum vessel signal at all cardiac phases. The ECG‐gated phase contrast line scan sequence has been used to image regions where cardiac pulsatility and respiratory motion compromise the quality of images obtained using standard spin warp angiographic methods. © 1992 Academic Press, Inc. Copyright © 1992 Wiley‐Liss, Inc., A Wiley Company
引用
收藏
页码:221 / 235
页数:15
相关论文
共 20 条
[1]   HIGH-SPEED LINE SCAN MR ANGIOGRAPHY [J].
BROWN, DG ;
RIEDERER, SJ ;
WRIGHT, RC ;
LIU, Y ;
FARZANEH, F .
MAGNETIC RESONANCE IN MEDICINE, 1990, 15 (03) :475-482
[2]   MAGNETIC-RESONANCE ANGIOGRAPHY [J].
DUMOULIN, CL ;
HART, HR .
RADIOLOGY, 1986, 161 (03) :717-720
[3]   PROJECTION ARTERIOGRAPHY AND VENOGRAPHY - INITIAL CLINICAL-RESULTS WITH MR [J].
EDELMAN, RR ;
WENTZ, KU ;
MATTLE, H ;
ZHAO, B ;
LIU, C ;
KIM, D ;
LAUB, G .
RADIOLOGY, 1989, 172 (02) :351-357
[4]   SPATIAL PRESATURATION - A METHOD FOR SUPPRESSING FLOW ARTIFACTS AND IMPROVING DEPICTION OF VASCULAR ANATOMY IN MR IMAGING [J].
FELMLEE, JP ;
EHMAN, RL .
RADIOLOGY, 1987, 164 (02) :559-564
[5]   RAPID LINE SCAN NMR ANGIOGRAPHY [J].
FRAHM, J ;
MERBOLDT, KD ;
HANICKE, W ;
GYNGELL, ML ;
BRUHN, H .
MAGNETIC RESONANCE IN MEDICINE, 1988, 7 (01) :79-87
[6]  
GRIST TG, 1989, RADIOLOGY, V173, P161
[7]   MR VASCULAR IMAGING WITH A FAST GRADIENT REFOCUSING PULSE SEQUENCE AND REFORMATTED IMAGES FROM TRANSAXIAL SECTIONS [J].
GULLBERG, GT ;
WEHRLI, FW ;
SHIMAKAWA, A ;
SIMONS, MA .
RADIOLOGY, 1987, 165 (01) :241-246
[8]   QUANTITATIVE FLOW MEASUREMENT WITH THE FAST FOURIER FLOW TECHNIQUE [J].
HENNIG, J ;
MURI, M ;
BRUNNER, P ;
FRIEDBURG, H .
RADIOLOGY, 1988, 166 (01) :237-240
[9]  
HENNIG J, 1990, 9TH ANN M SOC MAGN R, P163
[10]   MR ANGIOGRAPHY WITH TWO-DIMENSIONAL ACQUISITION AND 3-DIMENSIONAL DISPLAY - WORK IN PROGRESS [J].
KELLER, PJ ;
DRAYER, BP ;
FRAM, EK ;
WILLIAMS, KD ;
DUMOULIN, CL ;
SOUZA, SP .
RADIOLOGY, 1989, 173 (02) :527-532