ECHOCARDIOGRAPHIC PREDICTORS OF CANDIDACY FOR SUCCESSFUL TRANSCATHETER ATRIAL SEPTAL-DEFECT CLOSURE

被引:40
作者
ROSENFELD, HM [1 ]
VANDERVELDE, ME [1 ]
SANDERS, SP [1 ]
COLAN, SD [1 ]
PARNESS, IA [1 ]
LOCK, JE [1 ]
SPEVAK, PJ [1 ]
机构
[1] CHILDRENS HOSP,DEPT PEDIAT CARDIOL,BOSTON,MA 02115
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1995年 / 34卷 / 01期
关键词
ASD; CATHETERIZATION; DEVICE CLOSURE; ECHOCARDIOGRAM;
D O I
10.1002/ccd.1810340308
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We reviewed pre closure echocardiograms on all patients undergoing transcatheter atrial septal defect (ASD) closure with the Bard double-umbrella occluder device aided by simultaneous transesophageal echocardiography to determine precatheterization predictors of outcome, Transesophageal echocardiograms were performed on 28 of 132 patients (22%) undergoing device closure (age = 3-72 years, mean = 14 years; weight = 15-68 kg, mean = 35 kg), Three devices were removed because of unstable position, Of the remaining 25 patients, 21 had effective closure (residual flow diameter less than or equal to 3 mm) and 18 had favorable arm position (device arm on proper side of the septum and not in contact with an atrioventricular valve leaflet). Only ASD size predicted effective closure. All patients with a maximum defect size of < 13 mm had effective closure, Among the 17 patients with defects greater than or equal to 13 mm, 10 had effective closure, 4 had significant residual flow, and 3 had devices removed for unstable position, Atrial dimensions and rim size did not predict effective closure, There were no pre-closure predictors of favorable arm position which was associated only with the size of the device implanted. (C) 1995 Wiley-Liss, Inc.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 10 条
[1]   ECHOCARDIOGRAPHIC FOLLOW-UP OF ATRIAL SEPTAL-DEFECT AFTER CATHETER CLOSURE BY DOUBLE-UMBRELLA DEVICE [J].
BOUTIN, C ;
MUSEWE, NN ;
SMALLHORN, JF ;
DYCK, JD ;
KOBAYASHI, T ;
BENSON, LN .
CIRCULATION, 1993, 88 (02) :621-627
[2]  
CHAN KC, 1993, BRIT HEART J, V69, P52
[3]   EXPERIMENTAL ATRIAL SEPTAL-DEFECT CLOSURE WITH A NEW, TRANSCATHETER, SELF-CENTERING DEVICE [J].
DAS, GS ;
VOSS, G ;
JARVIS, G ;
WYCHE, K ;
GUNTHER, R ;
WILSON, RF .
CIRCULATION, 1993, 88 (04) :1754-1764
[4]  
FERREIRA SMAG, 1992, BRIT HEART J, V67, P316
[5]   SECUNDUM ATRIAL SEPTAL-DEFECT - NONOPERATIVE CLOSURE DURING CARDIAC-CATHETERIZATION [J].
KING, TD ;
THOMPSON, SL ;
STEINER, C ;
MILLS, NL .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1976, 235 (23) :2506-2509
[6]   ATRIAL SEPTAL-DEFECT OCCLUSION WITH THE BUTTONED DEVICE (A MULTIINSTITUTIONAL US TRIAL) [J].
LLOYD, TR ;
RAO, PS ;
BEEKMAN, RH ;
MENDELSOHN, AM ;
SIDERIS, EB .
AMERICAN JOURNAL OF CARDIOLOGY, 1994, 73 (04) :286-291
[7]   TRANSCATHETER CLOSURE OF ATRIAL SEPTAL-DEFECTS - EXPERIMENTAL STUDIES [J].
LOCK, JE ;
ROME, JJ ;
DAVIS, R ;
VANPRAAGH, S ;
PERRY, SB ;
VANPRAAGH, R ;
KEANE, JF .
CIRCULATION, 1989, 79 (05) :1091-1099
[8]   RELATIONSHIP OF ECHOCARDIOGRAPHIC, SHUNT FLOW, AND ANGIOGRAPHIC SIZE TO THE STRETCHED DIAMETER OF THE ATRIAL SEPTAL-DEFECT [J].
RAO, PS ;
LANGHOUGH, R .
AMERICAN HEART JOURNAL, 1991, 122 (02) :505-508
[9]   DOUBLE-UMBRELLA CLOSURE OF ATRIAL DEFECTS - INITIAL CLINICAL-APPLICATIONS [J].
ROME, JJ ;
KEANE, JF ;
PERRY, SB ;
SPEVAK, PJ ;
LOCK, JE .
CIRCULATION, 1990, 82 (03) :751-758
[10]   TRANS-ESOPHAGEAL ECHOCARDIOGRAPHY - TECHNIQUE, ANATOMIC CORRELATIONS, IMPLEMENTATION, AND CLINICAL-APPLICATIONS [J].
SEWARD, JB ;
KHANDHERIA, BK ;
OH, JK ;
ABEL, MD ;
HUGHES, RW ;
EDWARDS, WD ;
NICHOLS, BA ;
FREEMAN, WK ;
TAJIK, AJ .
MAYO CLINIC PROCEEDINGS, 1988, 63 (07) :649-680