EFFECT OF DIFFUSIOPHORESIS AND THERMOPHORESIS ON OVERALL PARTICLE COLLECTION EFFICIENCY OF SPRAY DROPLET SCRUBBERS

被引:34
作者
PILAT, MJ [1 ]
PREM, A [1 ]
机构
[1] UNIV WASHINGTON,DEPT CIVIL ENGN,SEATTLE,WA 98195
来源
JOURNAL OF THE AIR POLLUTION CONTROL ASSOCIATION | 1977年 / 27卷 / 10期
关键词
PARTICLE COLLECTION - SPRAY DROPLET SCRUBBERS;
D O I
10.1080/00022470.1977.10470521
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The overall particle collection efficiencies of spray scrubbers using monodisperse droplets of 100, 500, and 1000 microns diameter were calculated for the cases of evaporating and condensing droplets. The properties of the gas at the inlet to the spray scrubber were maintained constant at 150 degree F, 100% relative humidity, and 1 atmosphere pressure. At the liquid entrance to the spray scrubber, the water droplet temperature was 50 degree F for the condensing case and 180 degree F for the evaporating case. The liquid to gas flow rate ratio for all the calculations was held constant at 4 gal/1000 acf. The gas velocity in the co-current spray tower was 1 ft/sec in the downwind direction. The calculation results show that for the particles in the 0. 01 to 10 mu m diameter range, the overall spray scrubber particle collection efficiency is greater with the cooler 50 degree F water (condensing case) than with the warmer 180 degree F water (evaporating case).
引用
收藏
页码:982 / 988
页数:7
相关论文
共 6 条
[1]  
CALVERT S, 1973, 68020256 CONTR
[2]  
KLEINSCHMIDT RV, 1939, CHEM METALL ENG, V46, P487
[3]   CALCULATED PARTICLE COLLECTION EFFICIENCIES OF SINGLE DROPLETS INCLUDING INERTIAL IMPACTION, BROWNIAN DIFFUSION, DIFFUSIOPHORESIS AND THERMOPHORESIS [J].
PILAT, MJ ;
PREM, A .
ATMOSPHERIC ENVIRONMENT, 1976, 10 (01) :13-19
[4]  
ROWE PN, 1965, TRANS INST CHEM ENG, V43, pT14
[5]  
SLINN WGN, 1970, PRECIPITATION SCAVEN
[6]   EFFECT OF DIFFUSIOPHORESIS ON PARTICLE COLLECTION BY WET SCRUBBERS [J].
SPARKS, LE ;
PILAT, MJ .
ATMOSPHERIC ENVIRONMENT, 1970, 4 (06) :651-&