SELECTIVE ELECTRON-CAPTURE SENSITIZATION

被引:17
作者
SIEVERS, RE [1 ]
PHILLIPS, MP [1 ]
BARKLEY, RM [1 ]
WIZNER, MA [1 ]
BOLLINGER, MJ [1 ]
HUTTE, RS [1 ]
FEHSENFELD, FC [1 ]
机构
[1] NOAA,ENVIRONM RES LABS,AERON LAB,BOULDER,CO 80303
来源
JOURNAL OF CHROMATOGRAPHY | 1979年 / 186卷 / DEC期
基金
美国国家科学基金会;
关键词
D O I
10.1016/S0021-9673(00)95232-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
When nitrous oxide is added to nitrogen carrier gas, certain compounds can be detected with much greater sensitivity than is normally possible. This selective sensitization can be attributed to ion-molecule reactions between analytes being eluted and O- and NO- generated in situ in electron-capture detectors when the carrier gas contains nitrous oxide. The enhancement of response for various compounds by selective electron-capture sensitization (SECS) using nitrous oxide-doped nitrogen carrier gas has been observed for methane, ethane, n-propane, n-butane, n-pentane, n-hexane, benzene, ethanol, methylisobutylketone, hydrogen and carbon dioxide. With SECS, it becomes possible to detect picogram levels of several hydrocarbons with electron-capture detectors. For carbon dioxide the response is sensitized by a factor of 5000 in the presence of nitrous oxide; for methane the peaks are about 10 times larger; and for hydrogen the enhancement is about 40-fold greater than in the absence of nitrous oxide. Examination of the degree of sensitization (or desensitization, in the case of chlorofluorocarbons) may be useful as an indication of the identity of unknown peaks in a chromatogram if identical samples are detected in the presence and absence of a sensitizing gas such as nitrous oxide. Detector stability is not adversely affected by injection of microliter volumes of solvents. SECS has been used to detect hydrogen and methane at the 1-ppm level in samples of ambient air and human breath. © 1979.
引用
收藏
页码:3 / 14
页数:12
相关论文
共 15 条
[1]   LABORATORY STUDIES OF NEGATIVE-ION REACTIONS WITH ATMOSPHERIC TRACE CONSTITUENTS [J].
FEHSENFELD, FC ;
FERGUSON, EE .
JOURNAL OF CHEMICAL PHYSICS, 1974, 61 (08) :3181-3193
[2]   DETERMINATION OF LACTOSE-MALABSORPTION BY BREATH ANALYSIS WITH GAS-CHROMATOGRAPHY [J].
GEARHART, HL ;
BOSE, DP ;
SMITH, CA ;
MORRISON, RD ;
WELSH, JD ;
SMALLEY, TK .
ANALYTICAL CHEMISTRY, 1976, 48 (02) :393-398
[3]   OXYGEN DOPING OF CARRIER GAS IN MEASUREMENT OF HALOGENATED METHANES BY GAS-CHROMATOGRAPHY WITH ELECTRON-CAPTURE DETECTION [J].
GRIMSRUD, EP ;
MILLER, DA .
ANALYTICAL CHEMISTRY, 1978, 50 (08) :1141-1145
[4]   EFFECT OF OXYGEN ON RESPONSE OF A CONSTANT-CURRENT NI-63 ELECTRON-CAPTURE DETECTOR [J].
GRIMSRUD, EP ;
STEBBINS, RG .
JOURNAL OF CHROMATOGRAPHY, 1978, 155 (01) :19-34
[5]   PRODUCTION AND EXCRETION OF HYDROGEN GAS IN MAN [J].
LEVITT, MD .
NEW ENGLAND JOURNAL OF MEDICINE, 1969, 281 (03) :122-&
[6]   REACTIONS OF O- WITH N2, N2O, SO2, NH3, CH4, AND C2H4 AND C2H2- WITH O2 FROM 300 DEGREESK TO RELATIVE KINETIC ENERGIES OF APPROXIMATELY 2 EV [J].
LINDINGER, W ;
ALBRITTON, DL ;
FEHSENFELD, FC ;
FERGUSON, EE .
JOURNAL OF CHEMICAL PHYSICS, 1975, 63 (08) :3238-3242
[7]   NEGATIVE-ION REACTIONS IN N2O AT LOW ENERGIES [J].
MARX, R ;
MAUCLAIRE, G ;
FEHSENFELD, FC ;
DUNKIN, DB ;
FERGUSON, EE .
JOURNAL OF CHEMICAL PHYSICS, 1973, 58 (08) :3267-3273
[8]   FLOW-DRIFT TECHNIQUE FOR ION MOBILITY AND ION-MOLECULE REACTION-RATE CONSTANT MEASUREMENTS .3. NEGATIVE-ION REACTIONS OF O- WITH CO, NO, H2, AND D2 [J].
MCFARLAND, M ;
ALBRITTON, DL ;
FEHSENFELD, FC ;
FERGUSON, EE ;
SCHMELTEKOPF, AL .
JOURNAL OF CHEMICAL PHYSICS, 1973, 59 (12) :6629-6635
[9]  
PHILLIPS MP, ANAL CHEM
[10]   DIRECT DETERMINATION OF AMBIENT CARBON-DIOXIDE AND NITROUS-OXIDE WITH A HIGH-TEMPERATURE NI-63-ELECTRON-CAPTURE DETECTOR [J].
SIMMONDS, PG .
JOURNAL OF CHROMATOGRAPHY, 1978, 166 (02) :593-598