AUTOMATED, ONLINE QUANTIFICATION OF LEFT-VENTRICULAR DIMENSIONS AND FUNCTION BY ECHOCARDIOGRAPHY WITH BACKSCATTER IMAGING AND LATERAL GAIN COMPENSATION

被引:72
作者
PEREZ, JE [1 ]
KLEIN, SC [1 ]
PRATER, DM [1 ]
FRASER, CE [1 ]
CARDONA, H [1 ]
WAGGONER, AD [1 ]
HOLLAND, MR [1 ]
MILLER, JG [1 ]
SOBEL, BE [1 ]
机构
[1] WASHINGTON UNIV,DEPT PHYS,ST LOUIS,MO 63110
关键词
D O I
10.1016/0002-9149(92)90056-5
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
To provide on-line quantification of left ventricular cavity dimensions and function by echocardiography 60 control subjects and 10 patients with cardiac dysfunction were studied. A novel, ultrasound imaging system was used which was developed to detect and track, in real time, ventricular endocardial blood boundaries based on quantitative assessment of acoustic properties of tissue. In addition, lateral gain compensation, a robust and novel image enhancement procedure, was used to provide instantaneous measurement and display of cavity areas and functional indexes on a beat-by-beat basis within regions of interest drawn around the blood pool cavity. In control subjects, short-axis end-diastolic area averaged 13.1 +/- 3.7 cm2 (SD), end-systolic area 5.9 +/- 2.7 cm2, and fractional area change 55.6 +/- 11.2%. Apical views yielded corresponding values of 23.8 +/- 4.5 cm2, 15.5 +/- 3.4 cm2 and 34.7 +/- 7.8%. Instantaneous peak rate of cavity area change approximated 50 cm2/s in systole and 60 cm2/s in diastole in each view. Serial measurements of area and functional index were reproducible over intervals of 2 to 3 weeks. Patients with dilated ventricles exhibited average apical view area values of 49.1 +/- 6.1 cm2 and 43.1 +/- 4.9 cm2 in diastole and systole with a fractional area change of 12.2 +/- 3.0%. Thus, results with on-line echocardiographic backscatter imaging-assisted automated edge detection are reproducible and capable of delineating cardiac dysfunction conveniently, promptly and serially at the bedside.
引用
收藏
页码:1200 / 1205
页数:6
相关论文
共 23 条
[1]   INFLUENCE OF THE ORIENTATION OF MYOCARDIAL FIBERS ON ECHOCARDIOGRAPHIC IMAGES [J].
AYGEN, M ;
POPP, RL .
AMERICAN JOURNAL OF CARDIOLOGY, 1987, 60 (01) :147-152
[2]   COMPUTER-ASSISTED EDGE-DETECTION IN TWO-DIMENSIONAL ECHOCARDIOGRAPHY - COMPARISON WITH ANATOMIC DATA [J].
COLLINS, SM ;
SKORTON, DJ ;
GEISER, EA ;
NICHOLS, JA ;
CONETTA, DA ;
PANDIAN, NG ;
KERBER, RE .
AMERICAN JOURNAL OF CARDIOLOGY, 1984, 53 (09) :1380-1387
[3]   REPRODUCIBILITY OF LEFT-VENTRICULAR AREA AND VOLUME MEASUREMENTS USING A COMPUTER ENDOCARDIAL EDGE-DETECTION ALGORITHM IN NORMAL SUBJECTS [J].
CONETTA, DA ;
GEISER, EA ;
OLIVER, LH ;
MILLER, AB ;
CONTI, CR .
AMERICAN JOURNAL OF CARDIOLOGY, 1985, 56 (15) :947-952
[4]   REAL-TIME COMPUTERIZATION OF TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
GARCIA, E ;
GUERET, P ;
BENNETT, M ;
CORDAY, E ;
ZWEHL, W ;
MEERBAUM, S ;
CORDAY, S ;
SWAN, HJC ;
BERMAN, D .
AMERICAN HEART JOURNAL, 1981, 101 (06) :783-792
[5]  
Geiser E A, 1988, J Am Soc Echocardiogr, V1, P410
[6]  
Geiser E A, 1990, J Am Soc Echocardiogr, V3, P79
[7]   ANISOTROPY OF THE ULTRASONIC BACKSCATTER OF MYOCARDIAL TISSUE .2. MEASUREMENTS INVIVO [J].
MADARAS, EI ;
PEREZ, J ;
SOBEL, BE ;
MOTTLEY, JG ;
MILLER, JG .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1988, 83 (02) :762-769
[8]  
MASUYAMA T, 1989, J AM COLL CARDIOL, V14, P702
[9]   AUTOMATIC REAL-TIME ENDOCARDIAL EDGE-DETECTION IN TWO-DIMENSIONAL ECHOCARDIOGRAPHY [J].
MELTON, HE ;
COLLINS, SM ;
SKORTON, DJ .
ULTRASONIC IMAGING, 1983, 5 (04) :300-307
[10]   ULTRASONIC TISSUE CHARACTERIZATION WITH INTEGRATED BACKSCATTER - ACUTE MYOCARDIAL ISCHEMIA, REPERFUSION, AND STUNNED MYOCARDIUM IN PATIENTS [J].
MILUNSKI, MR ;
MOHR, GA ;
PEREZ, JE ;
VERED, Z ;
WEAR, KA ;
GESSLER, CJ ;
SOBEL, BE ;
MILLER, JG ;
WICKLINE, SA .
CIRCULATION, 1989, 80 (03) :491-503