POTENTIAL OF RADIOFREQUENCY BALLOON ANGIOPLASTY - WELD STRENGTHS, DOSE-RESPONSE RELATIONSHIP, AND CORRELATIVE HISTOLOGY

被引:9
作者
BECKER, GJ
LEE, BI
WALLER, BF
BARRY, KJ
KAPLAN, J
CONNOLLY, R
DREESEN, RG
NARDELLA, P
机构
[1] MEDITECH,WATERTOWN,MA
[2] MANSFIELD SCI INC,MANSFIELD,MA
[3] INDIANA UNIV,DEPT PATHOL,INDIANAPOLIS,IN 46223
[4] WASHINGTON HOSP CTR,DEPT CARDIOL,WASHINGTON,DC 20010
[5] TUFTS UNIV,NEW ENGLAND MED CTR,SURG RES LAB,BOSTON,MA 02111
关键词
Aorta; dissection; 56.74; 94.454; aorta; stenosis or obstruction; transluminal angioplasty; interventional procedures; experimental; 94.1299;
D O I
10.1148/radiology.174.3.174-3-1003
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Previous studies have established the feasibility of combining tissue heat generated by radio-frequency (RF) current and mechanical pressure to manage problems of percutaneous transluminal angioplasty (PTA) that are thought to cause postangioplasty restenosis (PARS). In the current in vitro study of normal and atherosclerotic human aortic layers (intima-media and media-adventitia) separated artificially, the purposes were to identify a dose-response relationship between the total RF energy delivered and the resultant weld strength between vascular tissues and to study the histologic correlates. Twenty-eight control and 100 experimental specimens were evaluated. The mean weld strength for all specimens with no RF current (at 0 J) was 4.1 g ± 2.0; at 100 J, 5.9 g ± 2.8; at 200 J, 28.5 g ± 3.3; at 300 J, 50.0 g ± 5.5; and at 500 J, 82.0 g ± 8.2. Inspection of treated specimens revealed vascular molding (depression in the surface corresponding in dimensions to those of the electrode gap in the treatment chamber). Histologic examination revealed necrosis in the region underlying the electrode gap, a hypocellular fusion zone, indistinct boundaries between welded specimen parts, and transition zones to normal histologic characteristics at either end of each specimen. RF energy combined with mechanical pressure produces dose-dependent thermal welds in artificially dissected vascular tissues, molding of vascular tissue, and cellular destruction in the media. These findings may have clinical application in the management or prevention of all forms of PARS in humans and in the treatment of spontaneous aortic dissection.
引用
收藏
页码:1003 / 1008
页数:6
相关论文
共 49 条
[1]  
Adams P C, 1987, Cardiovasc Clin, V18, P49
[2]   THE EFFECT OF RADIOFREQUENCY-GENERATED THERMAL-ENERGY ON THE MECHANICAL AND HISTOLOGIC CHARACTERISTICS OF THE ARTERIAL-WALL INVIVO - IMPLICATIONS FOR RADIOFREQUENCY ANGIOPLASTY [J].
BARRY, KJ ;
KAPLAN, J ;
CONNOLLY, RJ ;
NARDELLA, P ;
LEE, BI ;
BECKER, GJ ;
WALLER, BF ;
CALLOW, AD .
AMERICAN HEART JOURNAL, 1989, 117 (02) :332-341
[3]   LONG-TERM OCCLUSION OF THE PORCINE CYSTIC DUCT BY MEANS OF ENDOLUMINAL RADIO-FREQUENCY ELECTROCOAGULATION [J].
BECKER, CD ;
QUENVILLE, NF ;
BURHENNE, HJ .
RADIOLOGY, 1988, 167 (01) :63-68
[4]   RADIOFREQUENCY BALLOON ANGIOPLASTY RATIONALE AND PROOF OF PRINCIPLE [J].
BECKER, GJ ;
LEE, BI ;
WALLER, BF ;
BARRY, KJ ;
KAPLAN, J ;
CONNOLLY, R ;
DREESEN, RG ;
NARDELLA, P .
INVESTIGATIVE RADIOLOGY, 1988, 23 (11) :810-817
[5]  
COSSMAN D, 1978, ARCH SURG-CHICAGO, V113, P275
[6]  
ESSED CE, 1983, BRIT HEART J, V49, P393
[7]  
FAXON DP, 1984, AM J CARDIOL, V53, P72
[8]  
GIRALDO AA, 1985, ARCH PATHOL LAB MED, V109, P173
[9]  
HEIHLE JF, 1985, AM J CARDIOL, V56, P953
[10]  
HOLMES DR, 1984, AM J CARDIOL SC, V53, P77