THE ACCURACY OF THE BIOX 3700 PULSE OXIMETER IN PATIENTS RECEIVING VASOACTIVE THERAPY

被引:31
作者
IBANEZ, J
VELASCO, J
RAURICH, JM
机构
[1] Intensive Care Unit, Hospital Son Dureta, Palma De Mallorca, E-07014, C/ Andrea Doria
关键词
PULSE OXIMETRY; SHOCK; VASOACTIVE DRUGS;
D O I
10.1007/BF01690773
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The accuracy of pulse oximetry for the prediction of oxygen saturation of arterial blood in patients with shock has been hardly studied. This study was undertaken to determine if O2 arterial saturation estimated by the Biox 3700 pulse oximeter (SpO2) with an ear probe could reliably substitute for the measurements of O2 saturation (HbO2) with an IL-282 Co-Oximeter in samples of arterial blood obtained from 24 caucasian patients. All patients were mechanically ventilated and needed vasoactive drugs (dopamine and/or dobutamine). Of 24 patients 13 had shock: cardiogenic (n = 6) and septic (n = 7). The mean difference between HbO2 and SpO2 was 2.49% +/- 4.24, with a 95% confidence interval of 0.7% to 4.3% (p = 0.009). There were clinically important differences between both methods since in 9 of 24 patients (37%) SpO2 values were at least 4% lower or greater than HbO2. This disagreement was also apparent in patients with (6/13, 46%) or without shock (3/11, 27%). To conclude, pulse oximetry is not always a sufficiently reliable method to predict HbO2 in patients with or without shock treated with vasoactive drugs.
引用
收藏
页码:484 / 486
页数:3
相关论文
共 16 条
[1]  
BAKER SJ, 1987, ANESTHESIOLOGY, V67, P599
[2]   STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT [J].
BLAND, JM ;
ALTMAN, DG .
LANCET, 1986, 1 (8476) :307-310
[3]   NON-INVASIVE MONITORING OF ARTERIAL BLOOD-GASES - A REPORT OF THE ACCP SECTION ON RESPIRATORY PATHO-PHYSIOLOGY [J].
BURKI, NK ;
ALBERT, RK .
CHEST, 1983, 83 (04) :666-670
[4]  
CHAPMAN KR, 1986, CHEST, V4, P540
[5]  
DIES AL, 1987, CHEST, V91, P316
[6]   RELIABILITY OF PULSE OXIMETRY IN TITRATING SUPPLEMENTAL OXYGEN-THERAPY IN VENTILATOR-DEPENDENT PATIENTS [J].
JUBRAN, A ;
TOBIN, MJ .
CHEST, 1990, 97 (06) :1420-1425
[7]   EVALUATION OF THE OHMEDA 3700 PULSE OXIMETER - STEADY-STATE AND TRANSIENT-RESPONSE CHARACTERISTICS [J].
KAGLE, DM ;
ALEXANDER, CM ;
BERKO, RS ;
GIUFFRE, M ;
GROSS, JB .
ANESTHESIOLOGY, 1987, 66 (03) :376-380
[8]  
KIM SK, 1984, CRIT CARE MED, V2, P910
[9]   NONINVASIVE DETECTION OF PROFOUND ARTERIAL DESATURATIONS USING A PULSE OXIMETRY DEVICE [J].
MIHM, FG ;
HALPERIN, BD .
ANESTHESIOLOGY, 1985, 62 (01) :85-87
[10]   THE ACCURACY AND RESPONSE CHARACTERISTICS OF A SIMPLIFIED EAR OXIMETER [J].
REBUCK, AS ;
CHAPMAN, KR ;
DURZO, A .
CHEST, 1983, 83 (06) :860-864