The status of the dosimetry of high-energy photon and electron beams is analysed, taking into account the main developments in the field since the implementation of the IAEA Code of Practice in the Nordic countries. In electron beam dosimetry, energy-range relationships are discussed; Monte-Carlo results with different codes are compared with the experimentally derived empirical expression used in most protocols. Updated calculations of water-to-air stopping-power ratios following the changes in the Monte-Carlo code used to compute actual S(w,air) values are compared with the data included in most dosimetry protocols. The validity of the commonly used procedure to select stopping-power ratios for a clinical beam from the mean energy at the phantom surface and the depth of measurement, is analysed for 'realistic' electron beams. In photon beam dosimetry, calculated correction factors including the effect of the wall plus waterproofing sleeve and existing data on the shift of the effective point of measurement of an ionization chamber, are discussed. New calculations of medium-to-air stopping-power ratios and their correlation with the quality of the beam obtained from the convolution of Monte-Carlo kernels are presented together with their possible practical implications in dosimetry. Trends in Primary Standard Dosimetry Laboratories towards implementing calibrations in terms of absorbed dose to water are presented, emphasising controversial proposals for the specification of photon beam qualities. Plane-parallel ionization chambers are discussed regarding aspects that affect determinations of absorbed dose, either through the different methods used for the calibration of these chambers or by means of correction factors. Recent studies on the effect of the central electrode in Farmer-type cylindrical chambers are described.
引用
收藏
页码:483 / 500
页数:18
相关论文
共 112 条
[1]   CALCULATION AND APPLICATION OF POINT SPREAD FUNCTIONS FOR TREATMENT PLANNING WITH HIGH-ENERGY PHOTON BEAMS [J].
AHNESJO, A ;
ANDREO, P ;
BRAHME, A .
ACTA ONCOLOGICA, 1987, 26 (01) :49-56
[2]   IONIZATION-CHAMBER DOSIMETRY FOR PHOTON AND ELECTRON-BEAMS - THEORETICAL CONSIDERATIONS [J].
ALMOND, PR ;
SVENSSON, H .
ACTA RADIOLOGICA-THERAPY PHYSICS BIOLOGY, 1977, 16 (02) :177-186
[3]  
ANDRE L, 1985, MED BIOL ENG COMP S1, V23, P1169
[4]   CHAMBER-DEPENDENT WALL CORRECTION FACTORS IN DOSIMETRY [J].
ANDREO, P ;
NAHUM, A ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1986, 31 (11) :1189-1199
[5]   ABSORBED DOSE BEAM QUALITY FACTORS FOR THE DOSIMETRY OF HIGH-ENERGY PHOTON BEAMS [J].
ANDREO, P .
PHYSICS IN MEDICINE AND BIOLOGY, 1992, 37 (12) :2189-2211
[6]   STOPPING-POWER RATIO FOR A PHOTON SPECTRUM AS A WEIGHTED SUM OF THE VALUES FOR MONOENERGETIC PHOTON BEAMS [J].
ANDREO, P ;
NAHUM, AE .
PHYSICS IN MEDICINE AND BIOLOGY, 1985, 30 (10) :1055-1065
[7]   ON THE CALIBRATION OF PLANE-PARALLEL ION CHAMBERS USING CO-60 BEAMS [J].
ANDREO, P ;
LINDBORG, L ;
MEDIN, J .
MEDICAL PHYSICS, 1991, 18 (02) :326-327
[8]   Estimation of uncertainties in stopping-power ratios using Monte Carlo methods [J].
Andreo, P. ;
Fransson, A. .
Applied Radiation and Isotopes, 1992, 43 (11)
[9]   INFLUENCE OF ENERGY AND ANGULAR SPREAD ON STOPPING-POWER RATIOS FOR ELECTRON-BEAMS [J].
ANDREO, P ;
BRAHME, A ;
NAHUM, A ;
MATTSSON, O .
PHYSICS IN MEDICINE AND BIOLOGY, 1989, 34 (06) :751-768
[10]   DEPTH DOSE AND STOPPING-POWER DATA FOR MONOENERGETIC ELECTRON-BEAMS [J].
ANDREO, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1990, 51 (02) :107-121