DIRECT SAMPLE INJECTION INTO THE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC COLUMN IN THEOPHYLLINE MONITORING

被引:8
作者
KOUNO, Y
ISHIKURA, C
TAKAHASHI, N
HOMMA, M
OKA, K
机构
[1] TOKYO COLL PHARM,DIV CLIN PHARMACOL,HACHIOJI,TOKYO 19203,JAPAN
[2] BOHSEI PHARM CO,ISEHARA,KANAGAWA 25911,JAPAN
[3] TOKYO MED COLL HOSP,DEPT PHARM,SHINJUKU KU,TOKYO 160,JAPAN
来源
JOURNAL OF CHROMATOGRAPHY | 1990年 / 515卷
关键词
D O I
10.1016/S0021-9673(01)89327-4
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A small diatomaceous earth column was used for direct sample injection into a high-performance liquid chromatographic (HPLC) column for theophylline monitoring. The original design of this device has been improved so as to make it easily usable and disposable following use. It consists of a diatomaceous earth-packed polystyrene tube, the inner surface of which is coated with PTFE, having a capacity of ca. 5 μl of plasma or serum sample, and a stainless-steel needle for introducing an extract into the HPLC sample injector. Using this device together with an optimized injection solvent mixture, an accurate determination of theophylline can be carried out at low cost. The results obtained were comparable to those given by an immunological method, such as fluorescence polarization immunoassay. © 1990.
引用
收藏
页码:321 / 327
页数:7
相关论文
共 14 条
  • [1] LIQUID-CHROMATOGRAPHIC DETERMINATION OF THEOPHYLLINE CONCENTRATION WITH SYRINGE-TYPE MINICOLUMNS FOR DIRECT PLASMA INJECTION
    HOMMA, M
    OKA, K
    TAKAHASHI, N
    [J]. ANALYTICAL CHEMISTRY, 1989, 61 (07) : 784 - 787
  • [2] ACID-BASE FRACTIONATION OF LIPOPHILIC COMPONENTS IN HUMAN-URINE AND THEIR HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY EQUIPPED WITH MULTICHANNEL ULTRAVIOLET DETECTOR - AN APPLICATION TO XANTHINE DERIVATIVES
    KANG, XX
    OKA, K
    [J]. YAKUGAKU ZASSHI-JOURNAL OF THE PHARMACEUTICAL SOCIETY OF JAPAN, 1989, 109 (04): : 274 - 279
  • [3] RETENTION PROPERTIES OF INTERNAL-SURFACE REVERSED-PHASE SILICA PACKING AND RECOVERY OF DRUGS FROM HUMAN-PLASMA
    NAKAGAWA, T
    SHIBUKAWA, A
    SHIMONO, N
    KAWASHIMA, T
    TANAKA, H
    HAGINAKA, J
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 420 (02): : 297 - 311
  • [4] COMBINED USE OF RAPID-FLOW FRACTIONATION AND HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY FOR THE DETERMINATION OF SERUM TESTOSTERONE AND APPLICATION TO STUDY OF STRESS RESPONSE TO PHYSICAL EXERCISE
    OKA, K
    HIRANO, T
    NOGUCHI, M
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 423 : 285 - 291
  • [5] DETERMINATION OF CYCLOSPORINE-A IN THE SERUM OF KIDNEY-TRANSPLANT PATIENTS BY RAPID-FLOW FRACTIONATION AND NORMAL-PHASE HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    OKA, K
    HOSODA, K
    HIRANO, T
    SAKURAI, E
    KOZAKI, M
    [J]. JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1989, 490 (01): : 145 - 154
  • [6] EFFICIENT CHROMATOGRAPHIC FRACTIONATION OF STEROIDS IN HUMAN-SERUM THROUGH REGULATION OF LIQUID LIQUID DISTRIBUTION RATIOS
    OKA, K
    IJITSU, T
    MINAGAWA, K
    HARA, S
    NOGUCHI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 339 (02): : 253 - 261
  • [7] ONLINE EXTRACTION, EVAPORATION, AND INJECTION FOR LIQUID-CHROMATOGRAPHIC DETERMINATION OF SERUM CORTICOSTEROIDS
    OKA, K
    MINAGAWA, K
    HARA, S
    NOGUCHI, M
    MATSUOKA, Y
    KONO, M
    IRIMAJIRI, S
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (01) : 24 - 27
  • [8] HIGHLY SENSITIVE DETERMINATION OF KETOPROFEN IN HUMAN-SERUM AND URINE AND ITS APPLICATION TO PHARMACOKINETIC STUDY
    OKA, K
    AOSHIMA, S
    NOGUCHI, M
    [J]. JOURNAL OF CHROMATOGRAPHY, 1985, 345 (02): : 419 - 424
  • [9] OKA K, 1988, CLIN CHEM, V34, P557
  • [10] EXTRACTION-MONITORING AND RAPID FLOW FRACTIONATION FOR DETERMINATION OF SERUM CORTICOSTEROIDS
    OKA, K
    OHKI, N
    NOGUCHI, M
    MATSUOKA, Y
    IRIMAJIRI, S
    ABE, M
    TAKIZAWA, T
    [J]. ANALYTICAL CHEMISTRY, 1984, 56 (13) : 2614 - 2617