EFFECT OF LUMINANCE AND CONTRAST ON STEREOSCOPIC ACUITY

被引:11
作者
GEIB, T [1 ]
BAUMANN, C [1 ]
机构
[1] UNIV GIESSEN,INST PHYSIOL,AULWEG 129,W-6300 GIESSEN,GERMANY
关键词
D O I
10.1007/BF00920053
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
The threshold of binocular depth perception was measured in 11 healthy volunteers. A three-rod arrangement was employed in which both the luminance of the rods and that of the adapting field could be adjusted independently. This allowed fixing the contrast when the effect of luminance was studied or fixing the luminance when the effect of contrast was investigated. The observation distance was 400 mm. Thresholds were expressed as angular disparities and were based on 75% correct responses. Points of subjective equality were also determined. Lowest thresholds (2.85 ± 0.67 s of arc) were found for a moderate contrast of 0.5 whereas low (0.05) and high (0.95) contrast both produced significantly higher thresholds (luminance 250 cd/m2). Altering the field luminance (50, 250, 1600 cd/m2) under constant contrast conditions (0.95) did not measurably influence stereoscopic acuity. © 1990 Springer-Verlag.
引用
收藏
页码:310 / 315
页数:6
相关论文
共 24 条
[2]   ON EXISTENCE OF NEURONES IN HUMAN VISUAL SYSTEM SELECTIVELY SENSITIVE TO ORIENTATION AND SIZE OF RETINAL IMAGES [J].
BLAKEMORE, C ;
CAMPBELL, FW .
JOURNAL OF PHYSIOLOGY-LONDON, 1969, 203 (01) :237-+
[3]   The method of probits [J].
Bliss, C. I. .
SCIENCE, 1934, 79 (2037) :38-39
[4]  
BOURDON B, 1900, REV PHIL, V49, P74
[5]  
Finney D, 1952, PROBIT ANAL
[6]  
FISHER RA, 1963, STATISTICAL TABLES B
[7]  
Graham C.H., 1951, HDB EXPT PSYCHOL, P868
[8]  
HELMHOLTZ H, 1910, HDB PHYSL OPTIK, V3, P307
[9]  
Helmholtz Hermann, 1864, A VONGRAEFES ARCH OP, V10, P1
[10]   LIMIT OF SINGLE VISION IN STEREOPSIS DEPENDS ON CONTOUR SHARPNESS [J].
KULIKOWSKI, JJ .
NATURE, 1978, 275 (5676) :126-127