ESTIMATION OF GLOMERULAR-FILTRATION RATE FROM LOW-DOSE INJECTION OF IOHEXOL AND A SINGLE BLOOD-SAMPLE

被引:36
作者
THOMSEN, HS [1 ]
HVIDJACOBSEN, K [1 ]
机构
[1] UNIV COPENHAGEN,HERLEV HOSP,DEPT NUCL MED,DK-2730 HERLEV,DENMARK
关键词
CR-51; EDTA; GLOMERULAR FILTRATION RATE; IOHEXOL; X-RAY FLUORESCENCE;
D O I
10.1097/00004424-199104000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Clearance of a small dose of iohexol (7 g I) was compared with the glomerular filtration rate (GFR) marker Cr-51 EDTA in 11 healthy volunteers. The two tracers were injected simultaneously. The plasma concentration of iohexol was measured with x-ray fluorescence technique. Glomerular filtration rate was determined using blood samples drawn three and four hours after injection. An excellent correlation (0.92 < r < 0.97) between iohexol clearance and Cr-51 EDTA clearance was found. Glomerular filtration rate can be reliably determined with a low dose of iohexol and a single blood sample obtained three hours after the injection in persons with normal serum creatinine. This new method is a good alternative to the methods using radiopharmaceuticals; it causes no radioactive burden to the patients, increases patient comfort, reduces costs, and requires no special license.
引用
收藏
页码:332 / 336
页数:5