MEASUREMENT OF MARINE PICOPLANKTON CELL-SIZE BY USING A COOLED, CHARGE-COUPLED DEVICE CAMERA WITH IMAGE-ANALYZED FLUORESCENCE MICROSCOPY

被引:56
作者
VILES, CL
SIERACKI, ME
机构
[1] COLL WILLIAM & MARY,VIRGINIA INST MARINE SCI,GLOUCESTER POINT,VA 23062
[2] COLL WILLIAM & MARY,SCH MARINE SCI,GLOUCESTER POINT,VA 23062
关键词
D O I
10.1128/AEM.58.2.584-592.1992
中图分类号
Q81 [生物工程学(生物技术)]; Q93 [微生物学];
学科分类号
071005 ; 0836 ; 090102 ; 100705 ;
摘要
Accurate measurement of the biomass and size distribution of picoplankton cells (0.2 to 2.0-mu-m) is paramount in characterizing their contribution to the oceanic food web and global biogeochemical cycling. Image-analyzed fluorescence microscopy, usually based on video camera technology, allows detailed measurements of individual cells to be taken. The application of an imaging system employing a cooled, slow-scan charge-coupled device (CCD) camera to automated counting and sizing of individual picoplankton cells from natural marine samples is described. A slow-scan CCD-based camera was compared to a video camera and was superior for detecting and sizing very small, dim particles such as fluorochrome-stained bacteria. Several edge detection methods for accurately measuring picoplankton cells were evaluated. Standard fluorescent microspheres and a Sargasso Sea surface water picoplankton population were used in the evaluation. Global thresholding was inappropriate for these samples. Methods used previously in image analysis of nanoplankton cells (2 to 20-mu-m) also did not work well with the smaller picoplankton cells. A method combining an edge detector and an adaptive edge strength operator worked best for rapidly generating accurate cell sizes. A complete sample analysis of more than 1,000 cells averages about 50 min and yields size, shape, and fluorescence data for each cell. With this system, the entire size range of picoplankton can be counted and measured.
引用
收藏
页码:584 / 592
页数:9
相关论文
共 29 条
[1]  
Ballard DH, 1982, COMPUTER VISION
[2]  
BJORNSEN PK, 1986, APPL ENVIRON MICROB, V51, P1199
[3]   A NOVEL FREE-LIVING PROCHLOROPHYTE ABUNDANT IN THE OCEANIC EUPHOTIC ZONE [J].
CHISHOLM, SW ;
OLSON, RJ ;
ZETTLER, ER ;
GOERICKE, R ;
WATERBURY, JB ;
WELSCHMEYER, NA .
NATURE, 1988, 334 (6180) :340-343
[4]   MACIMAGE - A USER-FRIENDLY IMAGE-ANALYSIS SYSTEM FOR THE ACCURATE MENSURATION OF MARINE ORGANISMS [J].
ESTEP, KW ;
MACINTYRE, F ;
HJORLEIFSSON, E ;
SIEBURTH, JM .
MARINE ECOLOGY PROGRESS SERIES, 1986, 33 (03) :243-253
[5]  
Gonzalez R. C., 1987, DIGITAL IMAGE PROCES
[6]  
HAZRA R, IN PRESS APPL OPT
[7]   THE USE OF A CHARGE-COUPLED DEVICE FOR QUANTITATIVE OPTICAL MICROSCOPY OF BIOLOGICAL STRUCTURES [J].
HIRAOKA, Y ;
SEDAT, JW ;
AGARD, DA .
SCIENCE, 1987, 238 (4823) :36-41
[8]   USE OF NUCLEPORE FILTERS FOR COUNTING BACTERIA BY FLUORESCENCE MICROSCOPY [J].
HOBBIE, JE ;
DALEY, RJ ;
JASPER, S .
APPLIED AND ENVIRONMENTAL MICROBIOLOGY, 1977, 33 (05) :1225-1228
[9]  
Horn B., 1986, ROBOT VISION, DOI DOI 10.1137/1030032
[10]  
Inoue S, 1986, VIDEO MICROSCOPY