REJECTING ESCAPE EVENTS IN LARGE-VOLUME GE-DETECTORS BY A PULSE-SHAPE SELECTION PROCEDURE

被引:5
作者
DELZOPPO, A [1 ]
AGODI, C [1 ]
ALBA, R [1 ]
BELLIA, G [1 ]
CONIGLIONE, R [1 ]
LOUKACHINE, K [1 ]
MAIOLINO, C [1 ]
MIGNECO, E [1 ]
PIATTELLI, P [1 ]
SANTONOCITO, D [1 ]
SAPIENZA, P [1 ]
机构
[1] UNIV CATANIA,DIPARTIMENTO FIS,I-95124 CATANIA,ITALY
关键词
D O I
10.1016/0168-9002(93)90807-T
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The dependence of the response to gamma-rays of a large volume Ge detector on the interval width of a selected initial rise pulse slope is investigated. The number of escape events associated with a small pulse slope is found to be greater than the corresponding number of full energy events. An escape event rejection procedure based on the observed correlation between energy deposition and pulse shape is discussed. Such a procedure seems particularly suited for the design of highly granular large volume Ge detector arrays.
引用
收藏
页码:450 / 456
页数:7
相关论文
共 9 条
[1]   PERFORMANCE OF A SYMMETRIC BGO-NAI ANTI-COMPTON SHIELD [J].
ALBA, R ;
BELLIA, G ;
DELZOPPO, A .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1988, 271 (03) :553-556
[2]   PERFORMANCES OF LARGE VOLUME P-TYPE HPGE DETECTORS [J].
BELLIA, G ;
DELZOPPO, A ;
AGODI, C ;
ALBA, R ;
CONIGLIONE, R ;
MIGNECO, E ;
RUSSO, G ;
SAPIENZA, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 284 (2-3) :399-404
[3]   MULTIDETECTOR SYSTEM FOR THE SEARCH AND INVESTIGATION OF HIGH-SPIN, HIGH-ENERGY ISOMERS PRODUCED IN HEAVY-ION INDUCED NUCLEAR-REACTIONS [J].
BIALKOWSKI, J ;
JASTRZEBSKI, J ;
KLEPACKI, P ;
LUKASIAK, J ;
MOSZYNSKI, M ;
PREIBISZ, Z ;
SKULSKI, W ;
ANDRE, S ;
GENEVEY, J ;
GIZON, A ;
GIZON, J ;
MARGOTTON, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 204 (01) :91-99
[4]  
Knoll GF, 1979, RAD DETECTION MEASUR
[5]   APPLICATION OF A PULSE SHAPE SELECTION METHOD TO A TRUE COAXIAL GE(LI) DETECTOR FOR MEASUREMENTS OF NANOSECONDS HALF-LIVES [J].
MOSZYNSKI, M ;
BENGTSON, B .
NUCLEAR INSTRUMENTS & METHODS, 1970, 80 (02) :233-+
[6]   LIMITATION OF THE COMPTON SUPPRESSION IN GE-BGO COMPTON SUPPRESSION SPECTROMETERS [J].
MOSZYNSKI, M ;
BJERREGARD, JH ;
GAARDHOJE, JJ ;
HERSKIND, B ;
KNUDSEN, P ;
SLETTEN, G .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1989, 280 (01) :73-82
[7]  
NOLAN PJ, 1985, NUCL INSTRUM METH A, V236, P281
[8]   TIMING PROPERTIES OF COAXIAL HPGE DETECTORS [J].
ROBERTSON, BC ;
MALM, HL .
NUCLEAR INSTRUMENTS & METHODS, 1978, 150 (03) :401-405
[9]   INFLUENCE OF CHARGE COLLECTION CHARACTERISTICS ON HPGE DETECTOR TIMING PERFORMANCE [J].
ROBERTSON, BC .
NUCLEAR INSTRUMENTS & METHODS, 1980, 169 (03) :465-468