TRANSCATHETER OCCLUSION OF PATENT DUCTUS-ARTERIOSUS WITH ADJUSTABLE BUTTONED DEVICE - INITIAL CLINICAL-EXPERIENCE

被引:99
作者
RAO, PS
SIDERIS, EB
HADDAD, J
REY, C
HAUSDORF, G
WILSON, AD
SMITH, PA
CHOPRA, PS
机构
[1] HOSP CORACAO RIBEIRAO PRETO, RIBEIRAO PRETO, BRAZIL
[2] HOSP CARDIOL LILLE, SERV CARDIOL, LILLE, FRANCE
[3] GERMAN HEART CTR, DEPT PEDIAT CARDIOL, BERLIN, GERMANY
[4] UNIV WISCONSIN, SCH MED, DEPT PEDIAT, MADISON, WI 53706 USA
[5] UNIV WISCONSIN, SCH MED, DEPT SURG, MADISON, WI 53706 USA
关键词
PROTHESIS; OCCLUSION; HEART DEFECT; PEDIATRICS;
D O I
10.1161/01.CIR.88.3.1119
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Several devices are available for transcatheter occlusion of patent ductus arteriosus. Most of these devices either require complicated intracardiac maneuvering, have not been tried in humans, or need a large-sized sheath for implantation of the device. Methods and Results. During a 26-month period ending November 1992, 14 patients underwent transcatheter closure of patent ductus arteriosus with an adjustable buttoned device delivered via a 7F sheath under an institutional review board-approved custom-made device protocol. The children were 15 months to 8 years of age with weight range of 7.2 to 19 kg. The patent ductus arteriosus measured from 2 to 7.5 mm (median, 3 mm) at the narrowest diameter and was conical, short, or tubular. They were occluded with devices measuring 15 to 20 mm. The ratio of pulmonary to systemic flow decreased (P<.01) from 1.9+/-0.6 (mean+/-SD; range, 1.3 to 3.2) to 1.05+/-0.1 (1 to 1.3). Continuous murmur of patent ductus arteriosus disappeared in all except 1 patient. Small residual shunts were detected by color Doppler studies in 4 of 14 patients (29%). All patients were followed for 1 to 24 months (mean, 6+/-7 months). The device was intact in all patients, and no breakage of the wires was noted. No shunts were seen in 12 of 14 patients (86%), and minute residual shunts were seen in 2 children. No major complications were encountered. Conclusions. It is concluded that transcatheter closure of patient ductus arteriosus with the adjustable buttoned device is feasible and effective and can be accomplished via small 7F sheaths; a 7F sheath is adequate for all ductal sizes; and the adjustable length of the loop accommodated all types of patent ductus arteriosus. Clinical trials on a larger number of patients are warranted.
引用
收藏
页码:1119 / 1126
页数:8
相关论文
共 28 条
[1]  
BENSON L, 1993, TRANSCATHETER THERAP, P321
[2]   CATHETER OCCLUSION OF THE PERSISTENTLY PATENT DUCTUS-ARTERIOSUS [J].
DYCK, JD ;
BENSON, LN ;
SMALLHORN, JF ;
MCLAUGHLIN, PR ;
FREEDOM, RM ;
ROWE, RD .
AMERICAN JOURNAL OF CARDIOLOGY, 1988, 62 (16) :1089-1092
[3]  
Echigo S, 1990, ASAIO Trans, V36, pM195
[4]   PREVALENCE OF ADDITIONAL CARDIOVASCULAR ANOMALIES IN PATIENTS REFERRED FOR TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS [J].
GELB, BD ;
OLAUGHLIN, MP ;
MULLINS, CE .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1990, 16 (07) :1680-1686
[5]  
Hellenbrand W E, 1989, Cardiol Clin, V7, P351
[6]   PERCUTANEOUS CATHETER CLOSURE OF THE DUCTUS-ARTERIOSUS IN CHILDREN AND YOUNG-ADULTS [J].
KHAN, MAA ;
MULLINS, CE ;
NIHILL, MR ;
ALYOUSEF, S ;
ALOUFY, S ;
ABDULLAH, M ;
ALFAGIH, MR ;
SAWYER, W .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 64 (03) :218-221
[7]   ANGIOGRAPHIC CLASSIFICATION OF THE ISOLATED, PERSISTENTLY PATENT DUCTUS-ARTERIOSUS AND IMPLICATIONS FOR PERCUTANEOUS CATHETER OCCLUSION [J].
KRICHENKO, A ;
BENSON, LN ;
BURROWS, P ;
MOES, CAF ;
MCLAUGHLIN, P ;
FREEDOM, RM .
AMERICAN JOURNAL OF CARDIOLOGY, 1989, 63 (12) :877-880
[8]   TRANSCATHETER CLOSURE OF PATENT DUCTUS-ARTERIOSUS IN PEDIATRIC-PATIENTS [J].
LATSON, LA ;
HOFSCHIRE, PJ ;
KUGLER, JD ;
CHEATHAM, JP ;
GUMBINER, CH ;
DANFORD, DA .
JOURNAL OF PEDIATRICS, 1989, 115 (04) :549-553
[9]  
LESLIE J, 1977, INVEST RADIOL, V12, P1242
[10]   A NEW DEVICE FOR TRANSCATHETER CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS - A FEASIBILITY STUDY IN DOGS [J].
MAGAL, C ;
WRIGHT, KC ;
DUPRAT, G ;
WALLACE, S ;
GIANTURCO, C .
INVESTIGATIVE RADIOLOGY, 1989, 24 (04) :272-276