COLD FLOW REDUCED BY METAL BACKING - AN INVIVO ROENTGEN STEREOPHOTOGRAMMETRIC ANALYSIS OF UNICOMPARTMENTAL TIBIAL COMPONENTS

被引:18
作者
RYD, L
LINDSTRAND, A
STENSTROM, A
SELVIK, G
机构
[1] UNIV LUND,DEPT DIAGNOST RADIOL,S-22185 LUND,SWEDEN
[2] UNIV LUND,DEPT ANAT,S-22185 LUND,SWEDEN
来源
ACTA ORTHOPAEDICA SCANDINAVICA | 1990年 / 61卷 / 01期
关键词
D O I
10.3109/17453679008993058
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Thirty-six cases of unicompartmental arthroplasty for gonarthrosis were followed for 6 years. the arthroplasties were prepared for roentgen stereophotogrammetric analysis (RSA) by marking the tibial components and the tibial methaphysis with tantalum balls. Nineteen out of 24 cases with a polyethylene tibial component had an increase in intermarker distances signifying progressive enlargement of the prosthesis due to cold flow. the enlargement was up to 2.8 percent of the circumference and was greater for 9 mm than for 12 mm thick components. Twelve cases with a metal-backed tibial component showed no cold flow. No correlation between cold flow and demographic, clinical, or radiographic data was found. © 1990 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:21 / 25
页数:5
相关论文
共 23 条
[1]  
AHLBACK S, 1968, ACTA RADIOL S, V277
[2]   MECHANICAL TESTS ON TIBIAL COMPONENTS OF NON-HINGED KNEE PROSTHESES [J].
BARGREN, JH ;
DAY, WH ;
FREEMAN, MAR ;
SWANSON, SAV .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (02) :256-261
[3]   THE EFFECT OF CONFORMITY, THICKNESS, AND MATERIAL ON STRESSES IN ULTRAHIGH MOLECULAR-WEIGHT COMPONENTS FOR TOTAL JOINT REPLACEMENT [J].
BARTEL, DL ;
BICKNELL, VL ;
WRIGHT, TM .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1986, 68A (07) :1041-1051
[4]   FAILURE OF TOTAL KNEE ARTHROPLASTY DUE TO LOOSENING AND DEFORMATION OF TIBIAL COMPONENT [J].
DUCHEYNE, P ;
KAGAN, A ;
LACEY, JA .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 1978, 60 (03) :384-391
[5]   MECHANICS OF KNEE AND PROSTHESIS DESIGN [J].
GOODFELLOW, J ;
OCONNOR, J .
JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1978, 60 (03) :358-369
[6]   COMPARTMENTAL ARTHROPLASTY FOR GONARTHROSIS [J].
JONSSON, GT .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 :1-111
[7]  
KARRHOLM J, 1984, CLIN ORTHOP RELAT R, V191, P121
[8]   DEFORMATION AND LOOSENING OF THE TIBIAL COMPONENT IN KNEE ARTHROPLASTY WITH UNICOMPARTMENTAL ENDOPROSTHESES [J].
KNUTSON, K ;
JONSSON, G ;
ANDERSEN, JL ;
LARUSDOTTIR, H ;
LIDGREN, L .
ACTA ORTHOPAEDICA SCANDINAVICA, 1981, 52 (06) :667-673
[9]   USE OF A GUIDE INSTRUMENT FOR COMPARTMENTAL KNEE ARTHROPLASTY [J].
LINDSTRAND, A ;
BOEGARD, T ;
EGUND, N ;
THORNGREN, KG .
ACTA ORTHOPAEDICA SCANDINAVICA, 1982, 53 (04) :633-639
[10]  
Maquet P, 1967, Rev Chir Orthop Reparatrice Appar Mot, V53, P111