BLIND PLACEMENT OF PLASTIC LEFT DOUBLE-LUMEN TUBES

被引:15
作者
BRODSKY, JB [1 ]
MACARIO, A [1 ]
CANNON, WB [1 ]
MARK, JBD [1 ]
机构
[1] STANFORD UNIV,SCH MED,DEPT CARDIOTHORAC SURG,STANFORD,CA 94305
关键词
ANESTHESIA TECHNIQUES; INTUBATION; TRACHEAL; ENDOBRONCHIAL; EQUIPMENT; DOUBLE-LUMEN ENDOBRONCHIAL TUBES; SURGERY; THORACIC;
D O I
10.1177/0310057X9502300509
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
A prospective analysis of placement of left-sided plastic double-lumen tubes in 100 patients is presented. Intubation of the left bronchus was successfully accomplished using only auscultation and clinical signs (''blind'' placement) in 91 patients. Double-lumen tubes were positioned in less than five minutes in 84 patients. The most common problem encountered (30%) was initial intubation of the right main bronchus Seven of these patients required bronchoscopic assistance to guide the tube into the left bronchus. There were four minor intraoperative complications due to DLT malposition that were recognized and corrected by withdrawing the tube slightly back in the bronchus The plastic double-lumen tubes functioned properly during the procedure in all 100 patients.
引用
收藏
页码:583 / 586
页数:4
相关论文
共 13 条
[1]   CONTINUOUS SPIROMETRY FOR DETECTION OF DOUBLE-LUMEN ENDOBRONCHIAL TUBE DISPLACEMENT [J].
BARDOCZKY, GI ;
LEVARLET, M ;
ENGELMAN, E ;
DEFRANCQUEN, P .
BRITISH JOURNAL OF ANAESTHESIA, 1993, 70 (05) :499-502
[2]  
Benumof J L, 1993, J Cardiothorac Vasc Anesth, V7, P513, DOI 10.1016/1053-0770(93)90303-3
[3]   MARGIN OF SAFETY IN POSITIONING MODERN DOUBLE-LUMEN ENDOTRACHEAL-TUBES [J].
BENUMOF, JL ;
PARTRIDGE, BL ;
SALVATIERRA, C ;
KEATING, J .
ANESTHESIOLOGY, 1987, 67 (05) :729-738
[4]  
BRODSKY JB, 1991, ANESTH ANALG, V73, P570
[5]   MALPOSITION OF LEFT-SIDED DOUBLE-LUMEN ENDOBRONCHIAL TUBES [J].
BRODSKY, JB ;
SHULMAN, MS ;
MARK, JBD .
ANESTHESIOLOGY, 1985, 62 (05) :667-669
[6]  
Brodsky JB, 1983, ANESTHESIOLOGY REV, V10, P26
[7]   ADVANTAGES OF A NEW POLYVINYL-CHLORIDE DOUBLE-LUMEN TUBE IN THORACIC-SURGERY [J].
BURTON, NA ;
WATSON, DC ;
BRODSKY, JB ;
MARK, JBD .
ANNALS OF THORACIC SURGERY, 1983, 36 (01) :78-84
[8]   INTRAOPERATIVE MANIPULATION FOR POSITIONING OF DOUBLE-LUMEN TUBES [J].
COHEN, E ;
KIRSCHNER, PA ;
GOLDOFSKY, S .
ANESTHESIOLOGY, 1988, 68 (01) :170-170
[9]   ROBERTSHAW DOUBLE-LUMEN TUBES - A REAPPRAISAL 30 YEARS ON [J].
CONACHER, ID ;
HERREMA, IH ;
BATCHELOR, AM .
ANAESTHESIA AND INTENSIVE CARE, 1994, 22 (02) :179-183
[10]   PROPER LATERALIZATION OF LEFT-SIDED DOUBLE-LUMEN TUBES [J].
NEUSTEIN, SM ;
EISENKRAFT, JB .
ANESTHESIOLOGY, 1989, 71 (06) :996-997