Cardiac output was determined by means of radioactive microspheres, 15 ± 5 μm in diameter. Blood flow in the ascending aorta was measured by an electromagnetic flowmeter. In eight cats thirty-eight simultaneous measurements were made of cardiac output and aortic flow. The observations correlated well (r = 0.89), with a mean difference of 5.2% probably corresponding to coronary blood flow. Continuous flow recordings showed no alterations in aortic flow during the injections of microspheres; arterial blood pressure and heart rate remained unchanged even after six injections, each consisting of about 2 × 105 spheres per kg body weight. Tests for shunting of microspheres were performed and revealed shunt fractions in the systemic circulation of about 8% with no significant shunting through the lungs. The microsphere method for determining cardiac output is thought to be an accurate method, suitable for small and medium sized animals. © 1979 Informa UK Ltd All rights reserved: reproduction in whole or part not permitted.
引用
收藏
页码:415 / 421
页数:7
相关论文
共 18 条
[1]   MEASUREMENT OF CARDIAC-OUTPUT WITH AND ORGAN TRAPPING OF RADIOACTIVE MICROSPHERES [J].
ARCHIE, JP ;
FIXLER, DE ;
ULLYOT, DJ ;
HOFFMAN, JIE ;
UTLEY, JR ;
CARLSON, EL .
JOURNAL OF APPLIED PHYSIOLOGY, 1973, 35 (01) :148-154
[2]   SIMPLE RADIOACTIVE MICROSPHERE METHOD FOR MEASURING REGIONAL FLOW AND CARDIAC-OUTPUT [J].
BARTRUM, RJ ;
BERKOWITZ, DM ;
HOLLENBERG, NK .
INVESTIGATIVE RADIOLOGY, 1974, 9 (03) :126-132
[3]   SOME SOURCES OF ERROR IN MEASURING REGIONAL BLOOD FLOW WITH RADIOACTIVE MICROSPHERES [J].
BUCKBERG, GD ;
LUCK, JC ;
PAYNE, DB ;
HOFFMAN, JIE ;
ARCHIE, JP ;
FIXLER, DE .
JOURNAL OF APPLIED PHYSIOLOGY, 1971, 31 (04) :598-&
[4]  
CAPPELEN C, 1968, NEW FINDINGS BLOOD F
[5]   TOTAL AND REGIONAL CORONARY BLOOD FLOW MEASURED BY RADIOACTIVE MICROSPHERES IN CONSCIOUS AND ANESTHETIZED DOGS [J].
DOMENECH, RJ ;
HOFFMAN, JIE ;
NOBLE, MIM ;
SAUNDERS, KB ;
HENSON, JR ;
SUBIJANTO, S .
CIRCULATION RESEARCH, 1969, 25 (05) :581-+
[6]   NORMAL DISTRIBUTION OF CARDIAC OUTPUT IN UNANESTHETIZED RESTRAINED RHESUS MONKEY [J].
FORSYTH, RP ;
NIES, AS ;
WYLER, F ;
NEUTZE, J ;
MELMON, KL .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (06) :736-&
[7]   EFFECTS OF FLOW PROFILE ON ELECTROMAGNETIC FLOWMETER ACCURACY [J].
GOLDMAN, SC ;
MARPLE, NB ;
SCOLNIK, WL .
JOURNAL OF APPLIED PHYSIOLOGY, 1963, 18 (03) :652-&
[8]   RADIOACTIVE MICROSPHERE MEASUREMENT OF CARDIAC-OUTPUT AND REGIONAL TISSUE BLOOD-FLOW IN SHEEP [J].
HALES, JRS .
PFLUGERS ARCHIV-EUROPEAN JOURNAL OF PHYSIOLOGY, 1973, 344 (02) :119-132
[9]   VALIDITY STUDIES OF RADIOACTIVE MICROSPHERE METHOD FOR STUDY OF DISTRIBUTION OF CARDIAC OUTPUT, ORGAN BLOOD FLOW, AND RESISTANCE IN CONSCIOUS RHESUS MONKEY [J].
HOFFBRAND, BI ;
FORSYTH, RP .
CARDIOVASCULAR RESEARCH, 1969, 3 (04) :426-+
[10]   MEASUREMENT OF DISTRIBUTION OF CARDIAC OUTPUT [J].
KAIHARA, S ;
VANHEERD.PD ;
MIGITA, T ;
WAGNER, HN .
JOURNAL OF APPLIED PHYSIOLOGY, 1968, 25 (06) :696-&