FIBER OPTIC SENSOR FOR THE DETECTION OF POTASSIUM USING FLUORESCENCE ENERGY-TRANSFER

被引:37
作者
ROE, JN
SZOKA, FC
VERKMAN, AS
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT PHARMACEUT CHEM,SAN FRANCISCO,CA 94143
[2] UNIV CALIF SAN FRANCISCO,DEPT MED,SAN FRANCISCO,CA 94143
[3] UNIV CALIF SAN FRANCISCO,INST CARDIOVASC RES,DEPT PHYSIOL,SAN FRANCISCO,CA 94143
关键词
Absorbance; Energy transfer; Fibre optic sensor; Fluorescence; Potassium;
D O I
10.1039/an9901500353
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A fluorescence fibre optic sensor has been developed for measurement of the potassium concentration in aqueous solution based on the change in optical absorbance of the hydrophobic indicator 7-decyl-2-methyl-4(3′,5′- dichlorophen-4′-one)indonaphth-1-ol (MEDPIN). The sensor was constructed by dipping the distal end of a single optical fibre in a polyfvinyl chloride) (PVC) coating solution containing MEDPIN, a plasticiser, the ionophore valinomycin and the fluorescent dye 1,1′-dioctadecyl-3,3,3′, 3′-tetramethylindodicarbocyanine perchlorate [DilC18(5)]. The change in the absorbance of MEDPIN induced by potassium was detected from the quenching of the fluorescence of DilC18(5) due to energy transfer. Glass slides dipped in the PVC coating solution were used to establish the optical properties of the sensor. The potassium concentration was detected by the absorbance of MEDPIN at 650 nm and by the quenching of the DilC 18(5) fluorescence by MEDPIN. The fluorescence intensity and lifetime of DilC18(5) decreased by ca. 40% with the addition of 33 mM KCI, indicating a resonance energy transfer mechanism. Experiments with the fibre optic sensor showed a decrease in the fluorescence of 57% with increasing potassium concentration (0-5 mM) at pH 7.45. The potassium concentration giving a 50% decrease in the fluorescence (Kd) for the most sensitive probe was 0.05 mM KCI. The value of Kd was increased to 1.3 mM when the plasticiser was changed from 2-nitrophenyl octyl ether to tris(2-ethylhexyl) phosphate; however, the 90% response time increased from 10 s to 4.2 min. Sodium and other physiological ions, and pH (6-8), had little or no effect on the fluorescence of the probe; the reproducibility for the determination of the potassium concentration was better than 1% in both blood and aqueous buffers. These results provide a sensitive and selective fibre optic sensor for potassium for potential application to in vivo monitoring of the potassium concentration.
引用
收藏
页码:353 / 358
页数:6
相关论文
共 22 条
[1]   AN OPTICAL POTASSIUM-ION SENSOR [J].
ALDER, JF ;
ASHWORTH, DC ;
NARAYANASWAMY, R ;
MOSS, RE ;
SUTHERLAND, IO .
ANALYST, 1987, 112 (08) :1191-1192
[2]   VALINOMYCIN-BASED K+ SELECTIVE MICROELECTRODES WITH LOW ELECTRICAL MEMBRANE RESISTANCE [J].
AMMANN, D ;
CHAO, P ;
SIMON, W .
NEUROSCIENCE LETTERS, 1987, 74 (02) :221-226
[3]   OXONOL DYES AS MONITORS OF MEMBRANE-POTENTIAL - THE EFFECT OF VIRUSES AND TOXINS ON THE PLASMA-MEMBRANE POTENTIAL OF ANIMAL-CELLS IN MONOLAYER-CULTURE AND IN SUSPENSION [J].
BASHFORD, CL ;
ALDER, GM ;
GRAY, MA ;
MICKLEM, KJ ;
TAYLOR, CC ;
TUREK, PJ ;
PASTERNAK, CA .
JOURNAL OF CELLULAR PHYSIOLOGY, 1985, 123 (03) :326-336
[4]  
BUDESINSKY B, 1967, CHEM ANAL, V56, P31
[5]  
CHARLTON SC, 1982, CLIN CHEM, V28, P1857
[6]  
DUNITZ JD, 1973, STRUCTURE BONDING, V16
[7]  
FRIEDLER U, 1977, ANAL CHIM ACTA, V89, P111
[8]  
GOLCHINI K, IN PRESS AM J PHYSL
[9]   POTASSIUM-SELECTIVE PVC MEMBRANE ELECTRODES BASED ON BIS(CROWN ETHER) AND POLY(CROWN ETHER) [J].
KIMURA, K ;
MAEDA, T ;
TAMURA, H ;
SHONO, T .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1979, 95 (01) :91-101
[10]   THE MOLECULAR MECHANICS OF VALINOMYCIN .2. COMPARATIVE STUDIES OF ALKALI ION BINDING [J].
MASUT, RA ;
KUSHICK, JN .
JOURNAL OF COMPUTATIONAL CHEMISTRY, 1985, 6 (02) :148-155