ABSORBED DOSE TO OVARIES OR UTERUS DURING A I-131 THERAPEUTIC OF CANCER OR HYPER-THYROIDISM - COMPARISON BETWEEN INVIVO MEASUREMENTS BY TLD AND CALCULATIONS

被引:7
作者
BRIERE, J
PHILIPPON, B
机构
[1] Centre de Médecine Nucléaire, Service du Professeur Berger, B.P. Lyon Montchat, 69394 Lyon
来源
INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES | 1979年 / 30卷 / 10期
关键词
D O I
10.1016/0020-708X(79)90081-4
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
An LiF dosimeter placed inside the uterus will only give an approximate value of the dose delivered to gonads during theraphy by iodine-131. But we easily demonstrated that the dose measured by TLD dosimeter does not significantly differ for uterus and for ovaries, because of the similar position of the source organs. Consequently we have placed in volunteer patients a LiF dosimeter inside the uterus. Experimental results were compared to the dose calculated by Robertson and Gorman's(1) method for ovaries and for uterus. © 1979.