DEVELOPMENT OF A CLINICAL MEASURE OF POSTURAL CONTROL FOR ASSESSMENT OF ADAPTIVE SEATING IN CHILDREN WITH NEUROMOTOR DISABILITIES

被引:66
作者
FIFE, SE
ROXBOROUGH, LA
ARMSTRONG, RW
HARRIS, SR
GREGSON, JL
FIELD, D
机构
[1] SUNNY HILL HOSP CHILDREN, NEUROMOTOR PROGRAM, VANCOUVER V5M 3E8, BC, CANADA
[2] UNIV BRITISH COLUMBIA, SCH REHABIL MED, DEPT PEDIAT, VANCOUVER V6T 2B5, BC, CANADA
[3] SUNNY HILL HOSP CHILDREN, POSITIONING ASSESSMENT UNIT, VANCOUVER V5M 3E8, BC, CANADA
来源
PHYSICAL THERAPY | 1991年 / 71卷 / 12期
关键词
ADAPTIVE SEATING; NEUROMOTOR DISABILITIES; POSTURAL CONTROL;
D O I
10.1093/ptj/71.12.981
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The primary purposes of this article are to review the literature on seating assessment and to describe the development of a clinical evaluation scale, the Seated Postural Control Measure (SPCM), for use with children requiring adaptive seating systems. The SPCM is an observational scale of 22 seated postural alignment items and 12 functional movement items, each scored on a four-point, criterion-referenced scale. A secondary purpose of this article is to report the reliability of the seven-point Level of Sitting Scale (LSS). Interrater and test-retest reliability of the SPCM items and the one-item LSS were evaluated on a sample of 40 children with developmental disabilities who sat with and without their seating systems. Kappa values of .75 or higher were considered excellent, .40 to .74 as fair to good, and less than .40 as poor. The interrater reliability tests for the two seated conditions and the two test sessions conducted 3 weeks apart yielded overall item Kappa coefficient means of .45 for the alignment section and .85 for the function section. Test-retest results for the SPCM items were less satisfactory, with item Kappa coefficient means for the two seating conditions and raters of .35 and .29 for alignment and function, respectively. Reliability results did not appear to be consistently better among seating conditions, raters, or test sessions. Kappa coefficients for the LSS were fair to good for both interrater and test-retest reliability. Plans for future development of the SPCM and LSS are discussed.
引用
收藏
页码:981 / 993
页数:13
相关论文
共 52 条
[1]   VALIDITY AND RELIABILITY TESTING OF THE SCOLIOMETER [J].
AMENDT, LE ;
AUSEELLIAS, KL ;
EYBERS, JL ;
WADSWORTH, CT ;
NIELSEN, DH ;
WEINSTEIN, SL .
PHYSICAL THERAPY, 1990, 70 (02) :108-117
[2]  
ANDERSSON BJG, 1975, ORTHOP CLIN N AM, V6, P105
[3]  
Bardsley G I, 1984, Physiotherapy, V70, P59
[4]  
BENDIX T, 1983, SCAND J REHABIL MED, V15, P197
[5]  
BERGEN AF, 1990, POSITIONING FUNCTION, P3
[6]  
BOENIG B, 1989, SURVEY SEATING DELIV
[7]  
Campbell SK, 1990, PEDIATRIC PHYSICAL T, V2, P135, DOI DOI 10.1097/00001577-199002030-00005
[8]  
CASESMITH J, 1988, POSTURE FINE MOTORS
[9]  
Chandler LS, 1980, MOVEMENT ASSESSMENT
[10]  
CLARYTRIMM BL, 1991, PHYSICAL OCCUPATIONA, V10, P134