SENS-A-RAY CHARACTERISTICS WITH VARIATIONS IN-BEAM QUALITY

被引:8
作者
HARADA, T [1 ]
NISHIKAWA, K [1 ]
SHIBUYA, H [1 ]
HAYAKAWA, Y [1 ]
KUROYANAGI, K [1 ]
机构
[1] REGAM MED SYST,SUNDSVALL,SWEDEN
来源
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS | 1995年 / 80卷 / 01期
关键词
D O I
10.1016/S1079-2104(95)80028-X
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study examined the relationship between x-ray beam quality and image characteristics with the use of the Sens-A-Ray (Regam Medical Systems, Sundsvall, Sweden). To evaluate the x-ray response, properties of the image sensor, dark current and statistical noise, sensitivity, and contrast resolution were measured. Tube voltage, tube current, and exposure time were varied. Exposures were determined with the use of an ionization chamber. Pixel values beneath a lead strip were used to calculate dark current effects. Contrast was measured with pixel values from the images of a step-wedge. Dark current noise increased in proportion to exposure time. Although the sensitivity at each tube voltage was linear and proportional to the exposure, the gradient was inversely proportional to increased tube voltage. After subtraction of the dark current and statistical noise, the gradient of the sensitivity at low tube voltage remained steeper than at high tube voltages. Hence, sensitivity decreased with increased tube voltage. Sensitivity gradients-at each different tube current were similar. Irrespective of exposure, contrast resolution between adjoining step-wedge steps greater than or equal to 9 mm were too small to distinguish at 50 kVp. The gray levels for each step below 12 mm in thickness were distinguishable with 90 kVp. Increased dark current noise consequent to long exposure times narrowed the available gray scale range. Lower tube voltage resulted in higher sensitivity with larger gradients than higher tube voltages.
引用
收藏
页码:120 / 123
页数:4
相关论文
共 15 条
[1]   EVALUATION OF THE NEW RADIOVISIOGRAPHY SYSTEM IMAGE QUALITY [J].
BENZ, C ;
MOUYEN, F .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1991, 72 (05) :627-631
[2]   PIXEL PERCEPTION AND VOXEL VISION - CONSTRUCTS FOR A NEW PARADIGM IN MAXILLOFACIAL IMAGING [J].
FARMAN, AG ;
SCARFE, WC .
DENTOMAXILLOFACIAL RADIOLOGY, 1994, 23 (01) :5-9
[3]   DIRECT DIGITAL RADIOGRAPHY FOR THE DETECTION OF PERIODONTAL BONE-LESIONS [J].
FURKART, AJ ;
DOVE, SB ;
MCDAVID, WD ;
NUMMIKOSKI, P ;
MATTESON, S .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1992, 74 (05) :652-660
[4]  
Grondahl H G, 1992, Dentomaxillofac Radiol, V21, P198
[5]  
HAYAKAWA Y, 1994, EIZOU JYOUHOU MED, V26, P212
[6]  
KUROYANAGI K, 1994, J JPN DENT ASS, V47, P129
[7]   AN EVALUATION OF THE SENS-A-RAY DIGITAL DENTAL IMAGING-SYSTEM [J].
MCDONNELL, D ;
PRICE, C .
DENTOMAXILLOFACIAL RADIOLOGY, 1993, 22 (03) :121-126
[8]   DIRECT DIGITAL DENTAL-X-RAY IMAGING WITH VISUALIX/VIXA [J].
MOLTENI, R .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1993, 76 (02) :235-243
[9]   PRESENTATION AND PHYSICAL EVALUATION OF RADIO VISIOGRAPHY [J].
MOUYEN, F ;
BENZ, C ;
SONNABEND, E ;
LODTER, JP .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTICS, 1989, 68 (02) :238-242
[10]   SENS-A-RAY - A NEW SYSTEM FOR DIRECT DIGITAL INTRAORAL RADIOGRAPHY [J].
NELVIG, P ;
WING, K ;
WELANDER, U .
ORAL SURGERY ORAL MEDICINE ORAL PATHOLOGY ORAL RADIOLOGY AND ENDODONTOLOGY, 1992, 74 (06) :818-823