GLOBAL LEFT-VENTRICULAR PERFUSION - NONINVASIVE MEASUREMENT WITH CINE MR IMAGING AND PHASE-VELOCITY MAPPING OF CORONARY VENOUS OUTFLOW

被引:82
作者
VANROSSUM, AC
VISSER, FC
HOFMAN, MBM
GALJEE, MA
WESTERHOF, N
VALK, J
机构
[1] FREE UNIV AMSTERDAM,DEPT BIOMED ENGN,1081 HV AMSTERDAM,NETHERLANDS
[2] FREE UNIV AMSTERDAM,DEPT PHYSIOL,1081 HV AMSTERDAM,NETHERLANDS
[3] FREE UNIV AMSTERDAM,DEPT RADIOL,1081 HV AMSTERDAM,NETHERLANDS
[4] INTERUNIV CARDIOL INST NETHERLANDS,1081 HV AMSTERDAM,NETHERLANDS
关键词
CORONARY VESSELS; FLOW DYNAMICS; MR; MAGNETIC RESONANCE (MR); CINE STUDY;
D O I
10.1148/radiology.182.3.1535881
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Velocity and volumetric flow of left ventricular venous outflow in the distal coronary sinus were measured with magnetic resonance (MR) velocity mapping techniques in 24 healthy men. A total of 16-21 velocity maps were acquired throughout the cardiac cycle. To determine the accuracy of the MR velocity-mapping pulse sequence, measurements were obtained with a flow phantom. Mean blood flow was 144 mL/min +/- 62 (standard deviation); mean velocity, 2.1 cm/sec +/- 1.0; and mean cross-sectional area, 1.2 cm2. Phasic measurements revealed a biphasic flow pattern in the coronary sinus, with a first peak in systole (257 mL/min +/- 174) and a second peak in early diastole (1,090 mL/min +/- 487). The cross-sectional area varied between 0.5 cm2 +/- 0.2 at end diastole and 1.9 cm2 +/- 0.6 in systole, a finding that suggests a capacitance function for venous outflow. Mean blood flow measurements were in agreement with measurements obtained invasively in previous studies. It is concluded that MR velocity mapping can enable noninvasive measurement of coronary venous outflow and global left ventricular perfusion and may become clinically useful in assessment of coronary blood flow reserve.
引用
收藏
页码:685 / 691
页数:7
相关论文
共 30 条
[1]  
Anrep GV, 1927, HEART, V14, P111
[2]  
BRADLEY AB, 1984, CARDIOVASC CLIN, V14, P67
[3]   PHASIC VOLUMETRIC CORONARY VENOUS OUTFLOW PATTERNS IN CONSCIOUS DOGS [J].
CANTY, JM ;
BROOKS, A .
AMERICAN JOURNAL OF PHYSIOLOGY, 1990, 258 (05) :H1457-H1463
[4]   THE APPLICATION OF PHASE-SHIFTS IN NMR FOR FLOW MEASUREMENT [J].
FIRMIN, DN ;
NAYLER, GL ;
KILNER, PJ ;
LONGMORE, DB .
MAGNETIC RESONANCE IN MEDICINE, 1990, 14 (02) :230-241
[5]   MEASUREMENT OF CORONARY SINUS BLOOD FLOW BY CONTINUOUS THERMODILUTION IN MAN [J].
GANZ, W ;
TAMURA, K ;
MARCUS, HS ;
DONOSO, R ;
YOSHIDA, S ;
SWAN, HJC .
CIRCULATION, 1971, 44 (02) :181-&
[6]  
GROSSMAN W, 1991, CARDIAC CATHETERIZAT, P47
[7]  
HOOD WB, 1968, BRIT HEART J, V30, P105
[8]  
Johnson JR, 1937, AM J PHYSIOL, V118, P38
[9]  
KAJIYA F, 1985, Heart and Vessels, V1, P16, DOI 10.1007/BF02066482
[10]  
KILPATRICK D, 1982, AM J PHYSIOL, V242, P1111