LIQUID-CHROMATOGRAPHIC ANALYSIS OF 9-AMINOCAMPTOTHECIN IN PLASMA MONITORED BY FLUORESCENCE INDUCED UPON POSTCOLUMN ACIDIFICATION

被引:26
作者
SUPKO, JG
MALSPEIS, L
机构
[1] Laboratory of Pharmaceutical Chemistry, Developmental Therapeutics Program, Division of Cancer Treatment, National Cancer Institute, Frederick
来源
JOURNAL OF LIQUID CHROMATOGRAPHY | 1992年 / 15卷 / 18期
基金
美国国家卫生研究院;
关键词
D O I
10.1080/10826079208020883
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Through preclinical studies by the Developmental Therapeutics Program of the National Cancer Institute with 9-amino-20(S)-camptothecin (AC), this new investigational anticancer agent will soon enter phase I clinical trials in cancer patients. During initial attempts to monitor the drug in biological fluids, it became evident that the presence of an amino group on the camptothecin A-ring suppressed the intense native fluorescence characteristic of the unsubstituted compound. However, subsequent spectrofluorometric studies revealed that the fluorescence of AC was highly pH-dependent in a manner not typically exhibited by aromatic amines. The uncharged species that exists in neutral and weakly acidic solution is nonfluorescent. Protonation of the C-9 amino group proceeds with the development of fluorescence, the intensity of which is optimum in moderately acidic solution of apparent pH 1.7-2.3. Under more strongly acidic conditions, fluorescent intensity again diminishes due to further protonation at the quinoline nitrogen atom. Therefore, postcolumn acidification prior to fluorescence detection provided a convenient and sensitive method to monitor the elution of AC during liquid chromatography. Following protein precipitation induced by mixing with a solution of the internal standard, camptothecin, in methanol chilled to -70-degrees-C, plasma samples were separated on a 5 mum Ultrasphere ODS column (4.6 mm x 25 cm) using an isocratic mobile phase composed of acetonitrile-methanol-0.1 M ammonium acetate buffer, pH 5.5 (23:10:67, v/v/v) at a flow rate of 1.0 ml/min. Prior to detection, the column effluent was mixed inline with 0.3 M aqueous trifluoroacetic acid at a flow rate of 0.3 ml/min and ambient temperature. Fluorescence was then monitored using an excitation wavelength of 352 nm and a 418 nm emission cutoff filter. Typical retention times of the drug and internal standard were 7 and 12 min, respectively. Employing sample volumes of 50 mul, the lowest plasma concentration of AC included in the standard curve, 13.3 nM (5.0 ng/ml) was quantified with a 7.63% coefficient of variation (n = 10).
引用
收藏
页码:3261 / 3283
页数:23
相关论文
共 28 条
[1]   PRODRUG ANALOGS OF THE ANTI-TUMOR ALKALOID CAMPTOTHECIN [J].
ADAMOVICS, JA ;
HUTCHINSON, CR .
JOURNAL OF MEDICINAL CHEMISTRY, 1979, 22 (03) :310-314
[2]  
CHABOT G G, 1991, Proceedings of the American Association for Cancer Research Annual Meeting, V32, P175
[3]  
CREAVEN PJ, 1973, CANCER CHEMOTH REP 1, V57, P175
[4]  
CREAVEN PJ, 1972, CANCER CHEMOTH REP 1, V56, P573
[5]  
ENG WK, 1988, MOL PHARMACOL, V34, P755
[6]  
FASSBERG J, 1992, IN PRESS J PHARM SCI
[7]  
GOTTLIEB JA, 1970, CANCER CHEMOTH REP 1, V54, P461
[8]  
GOTTLIEB JA, 1972, CANCER CHEMOTH REP 1, V56, P103
[9]  
HART LG, 1969, CANCER CHEMOTH REP 1, V53, P211
[10]  
Hartwell JL, 1969, ADV PHARMACOL CHEMOT, V7, P117, DOI 10.1016/S1054-3589(08)60561-X