DAILY DOSIMETRIC QUALITY-CONTROL OF THE MM50 RACETRACK MICROTRON USING AN ELECTRONIC PORTAL IMAGING DEVICE

被引:22
作者
DIRKX, MLP
KROONWIJK, M
DEBOER, JCJ
HEIJMEN, BJM
机构
[1] Dr. Daniel den Hoed Cancer Center, Department of Clinical Physics, 3075 EA Rotterdam
关键词
DOSIMETRIC QUALITY CONTROL; SCANNING BEAM; RACETRACK MICROTRON; PORTAL IMAGING;
D O I
10.1016/0167-8140(95)01588-8
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The MM50 Racetrack Microtron, suited for advanced three-dimensional conformal radiotherapy techniques, is a complex machine in various respects. Therefore, for a number of gantry angles, daily quality control of the absolute output and fluence profiles of the scanned beams are mandatory. For the applied photon beams, a fast method for these daily checks, based on dosimetric measurements with the Philips SRI-100 Electronic Portal Imaging Device (EPID), has been developed and tested. Open beams are checked for four different gantry angles; for gantry angle 0, a wedged field is checked as well. Performing and analyzing the measurements takes about 10 min. The applied EPID has favourable characteristics for dosimetric quality control measurements: absolute output measurements reproduce within 0.5% (1 SD) and the reproducibility of relative (2D) beam profile measurements is 0.2% (1 SD). The day-to-day sensitivity stability over a period of one month is 0.6% (1 SD). Measured grey scale values are within 0.2% linear with the applied dose. The 2D fluence profile of the 25 MV photon beam of the MM50 is very stable in time: during a period of 5 months a maximum fluctuation of 2.2% has been observed. Once, a deviation in the cGy/MU-value of 6% was detected. There is no interlock in the MM50-system that would have prevented patient treatment with this strongly deviating output. Based on the results of this study and on clinical requirements regarding acceptability of deviations of beam characteristics, a protocol has been developed including action levels for additional investigations and, if necessary, adjustment of the beam characteristics.
引用
收藏
页码:55 / 60
页数:6
相关论文
共 9 条
[1]   ELECTRON-BEAM CHARACTERISTICS OF THE 50-MEV RACETRACK MICROTRON [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1992, 19 (02) :307-315
[2]   MATCHING OF ELECTRON AND PHOTON BEAMS WITH A MULTI-LEAF COLLIMATOR [J].
KARLSSON, M ;
ZACKRISSON, B .
RADIOTHERAPY AND ONCOLOGY, 1993, 29 (03) :317-326
[3]   PHOTON-BEAM CHARACTERISTICS ON THE MM50 RACETRACK MICROTRON AND A NEW APPROACH FOR BEAM QUALITY DETERMINATION [J].
KARLSSON, M ;
NYSTROM, H ;
SVENSSON, H .
MEDICAL PHYSICS, 1993, 20 (01) :143-149
[4]   INITIAL CLINICAL-EXPERIENCE WITH COMPUTER-CONTROLLED CONFORMAL RADIOTHERAPY OF THE PROSTATE USING A 50-MEV MEDICAL MICROTRON [J].
MAGERAS, GS ;
FUKS, Z ;
OBRIEN, J ;
BREWSTER, LJ ;
BURMAN, C ;
CHUI, CS ;
LEIBEL, SA ;
LING, CC ;
MASTERSON, ME ;
MOHAN, R ;
KUTCHER, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04) :971-978
[5]   PRECLINICAL EVALUATION OF THE RELIABILITY OF A 50 MEV RACETRACK MICROTRON [J].
MASTERSON, ME ;
MAGERAS, GS ;
LOSASSO, T ;
JORESKOG, E ;
LARSSON, LG ;
TSIRAKIS, B ;
FEBO, R ;
MOHAN, R ;
LING, CC ;
LEIBEL, SA ;
FUKS, Z ;
KUTCHER, GJ .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 28 (05) :1219-1227
[6]   THE 50 MEV RACETRACK MICROTRON AT THE ROYAL-INSTITUTE-OF-TECHNOLOGY-STOCKHOLM [J].
ROSANDER, S ;
SEDLACEK, M ;
WERNHOLM, O ;
BABIC, H .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH, 1982, 204 (01) :1-20
[7]   GENERATION OF ARBITRARY INTENSITY PROFILES BY DYNAMIC JAWS OR MULTILEAF COLLIMATORS [J].
SPIROU, SV ;
CHUI, CS .
MEDICAL PHYSICS, 1994, 21 (07) :1031-1041
[8]   AN ANALYTICAL SOLUTION FOR THE DYNAMIC CONTROL OF MULTILEAF COLLIMATORS [J].
SVENSSON, R ;
KALLMAN, P ;
BRAHME, A .
PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (01) :37-61
[9]  
VISSER AG, 1990, INT J RADIAT ONCOL, V18, P41