PORTAL AND HEPATIC VEINS - ACCURACY OF MARGIN ECHOES FOR DISTINGUISHING INTRA-HEPATIC VESSELS

被引:21
作者
CHAFETZ, N [1 ]
FILLY, RA [1 ]
机构
[1] UNIV CALIF SAN FRANCISCO,DEPT RADIOL,SAN FRANCISCO,CA 94143
关键词
D O I
10.1148/130.3.725
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
One hundred randomly selected sonograms were retrospectively reviewed to determine the accuracy of employing the margin characteristics of intrahepatic venous radicals to distinguish portal from hepatic veins; 99% of intrahepatic portal veins demonstrated high amplitude acoustic margins. However, one or more hepatic veins also had high amplitude acoustic margins in 29% of patients in whom intraparenchymal hepatic veins were identified. The authors conclude that an intrahepatic venous structure without an echogenic border is almost invariably an hepatic vein, although other anatomical features should be considered for proper classification of intrahepatic venous structures which demonstrate high amplitude echoes surrounding the lumen.