THE THOMAS SHUNT REVISITED

被引:7
作者
FREEDMAN, BI [1 ]
ANDERSON, RL [1 ]
TUTTLE, AB [1 ]
CANZANELLO, VJ [1 ]
机构
[1] WAKE FOREST UNIV,BOWMAN GRAY SCH MED,DEPT PUBL HLTH SCI,WINSTON SALEM,NC
关键词
HEMODIALYSIS; VASCULAR ACCESS; THOMAS SHUNT;
D O I
10.1016/S0272-6386(12)70201-9
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
During a 10-year period, 57 external Thomas femoral shunts (TS) were placed in 43 patients for chronic hemodialysis access. Median shunt survival was 28 months (range, 0.5 to 132). Sixty-three percent (36/57) of shunts are presently functional or functioned until the time of patient death from unrelated cause or removal after renal transplantation. The remaining 37% (21/57) failed after a mean duration of 18 months (range, 2 to 40). Causes of failure were thrombosis (57%), refractory infection (24%), and failure during surgical revision (19%). There were no shunt-related deaths. Race, sex, the presence of diabetes mellitus or hypertension, and prior surgical revision of access did not adversely affect shunt survival. These results support the TS as a viable means of chronic vascular access for hemodialysis patients who cannot receive further upper arm accesses. © 1992, National Kidney Foundation, Inc.. All rights reserved.
引用
收藏
页码:45 / 48
页数:4
相关论文
共 11 条
[1]  
De Rosa P, 1986, Ital J Surg Sci, V16, P209
[2]  
MASON R, 1984, ANGIOACCESS PRINCIPL, P107
[3]   SUCCESSFUL USE OF LARGE-VESSEL APPLIQUE (THOMAS) SHUNTS ON ILIAC VESSELS [J].
MAY, J ;
JOHNSON, JR ;
HURLEY, B ;
TILLER, D ;
SHEIL, AGR .
MEDICAL JOURNAL OF AUSTRALIA, 1972, 1 (15) :734-&
[4]   LONG-TERM EXPERIENCE OF THOMAS SHUNTS ON THE ILIAC VESSELS [J].
MEECH, PR ;
HARDIE, IR ;
HARTLEY, LCJ ;
WOODRUFF, PWH ;
STRONG, RW ;
CLUNIE, GJA .
AUSTRALIAN AND NEW ZEALAND JOURNAL OF SURGERY, 1981, 51 (02) :161-165
[5]   VASCULAR ACCESS FOR HEMODIALYSIS - PATENCY RATES AND RESULTS OF REVISION [J].
PALDER, SB ;
KIRKMAN, RL ;
WHITTEMORE, AD ;
HAKIM, RM ;
LAZARUS, JM ;
TILNEY, NL .
ANNALS OF SURGERY, 1985, 202 (02) :235-239
[6]  
PICCHI G, 1986, ITAL J SURG SCI, V4, P301
[7]  
SANTIAGO.EA, 1972, SURG GYNECOL OBSTETR, V134, P835
[8]   SUCCESSFUL USE OF DOUBLE-LUMEN, SILICONE-RUBBER CATHETERS FOR PERMANENT HEMODIALYSIS ACCESS [J].
SHUSTERMAN, NH ;
KLOSS, K ;
MULLEN, JL .
KIDNEY INTERNATIONAL, 1989, 35 (03) :887-890
[10]  
THOMAS GI, 1969, T AM SOC ART INT ORG, V15, P288