CALIBRATION OF A REPLACEMENT PREPARATION FOR THE INTERNATIONAL STANDARD FOR RABIES IMMUNOGLOBULIN

被引:20
作者
LYNG, J
机构
[1] Int Laboratory Biological Standards, Statens Seruminstitut
关键词
D O I
10.1006/biol.1994.1036
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A proposed replacement preparation for the International Standard for Rabies Immunoglobulin was calibrated by means of two assay methods, a neutralization test in mice (MNT) and a neutralization test in cell culture (RFFIT). The calibration was made as an international collaborative assay comprising nine laboratories in eight countries. The results obtained in this study confirm earlier observations about occasional unexplainable differences between relative potencies obtained by the two methods. They also confirm the apparent reliability of the RFFIT, Based on the results obtained the proposed replacement preparation has been established as the second International Standard for Rabies Immunoglobulin with a defined unitage of 30 International Units of Rabies Antibodies in each ampoule.
引用
收藏
页码:249 / 255
页数:7
相关论文
共 17 条
[1]  
Atanasiu P, 1973, Monogr Ser World Health Organ, P314
[2]  
FINNEY DJ, 1978, STATISTICAL METHOD B
[3]   A COLLABORATIVE STUDY TO ESTABLISH AN INTERNATIONAL STANDARD RABIES IMMUNOGLOBULIN OF HUMAN-ORIGIN [J].
FITZGERALD, EA ;
RASTOGI, SC .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1985, 13 (04) :327-333
[4]   COLLABORATIVE STUDY ON THE TESTING OF RABIES IMMUNE GLOBULIN (HUMAN) BY THE MOUSE NEUTRALIZATION TEST (MNT) AND THE RAPID FLUORESCENT FOCUS INHIBITION TEST (RFFIT) [J].
FITZGERALD, EA ;
CABASSO, VJ ;
SMITH, JS ;
RASTOGI, SC .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1979, 7 (01) :67-72
[5]   LABORATORY EVALUATION OF IMMUNE-RESPONSE TO RABIES VACCINE [J].
FITZGERALD, EA ;
GALLAGHER, M ;
HUNTER, WS ;
SPIVEY, RJ ;
SELIGMANN, EB .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1978, 6 (02) :101-109
[6]   COLLABORATIVE STUDY ON POTENCY TESTING OF ANTIRABIES GLOBULIN [J].
FITZGERALD, EA ;
BAER, GM ;
CABASSO, VJ ;
VALLANCOURT, RJ .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1975, 3 (03) :273-278
[7]   HUMAN RABIES IMMUNOGLOBULIN ASSAYED BY THE RAPID FLUORESCENT FOCUS INHIBITION TEST SUPPRESSES ACTIVE RABIES IMMUNIZATION [J].
GLUCK, R ;
WEGMANN, A ;
KELLER, H ;
HOSKINS, JM ;
GERMANIER, R .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1987, 15 (02) :177-183
[8]   THE MOUSE NEUTRALIZATION TEST IN COMPARISON WITH THE RAPID FLUORESCENT FOCUS INHIBITION TEST - DIFFERENCES IN THE RESULTS IN RABIES ANTIBODY DETERMINATIONS [J].
HAASE, M ;
SEINSCHE, D ;
SCHNEIDER, W .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1985, 13 (02) :123-128
[9]  
Kurz J, 1986, Dev Biol Stand, V64, P99
[10]   MEASUREMENT OF RABIES ANTIBODY - COMPARISON OF MOUSE NEUTRALIZATION TEST (MNT) WITH RAPID FLUORESCENT FOCUS INHIBITION TEST (RFFIT) [J].
LOUIE, RE ;
DOBKIN, MB ;
MEYER, P ;
CHIN, B ;
ROBY, RE ;
HAMMAR, AH ;
CABASSO, VJ .
JOURNAL OF BIOLOGICAL STANDARDIZATION, 1975, 3 (04) :365-373