EVIDENCE FOR FALSE ANEUPLOID PEAKS IN FLOW CYTOMETRIC ANALYSIS OF PARAFFIN-EMBEDDED TISSUE

被引:61
作者
JOENSUU, H
ALANEN, KA
KLEMI, PJ
AINE, R
机构
[1] UNIV TURKU,CENT HOSP,DEPT PATHOL,SF-20520 TURKU 52,FINLAND
[2] UNIV TURKU,CENT HOSP,DEPT PATHOL,SF-20520 TURKU 52,FINLAND
[3] TAMPERE UNIV,CENT HOSP,DEPT PATHOL,SF-33520 TAMPERE,FINLAND
来源
CYTOMETRY | 1990年 / 11卷 / 03期
关键词
Autolysis; DNA content; fixation artifacts; normal tissue;
D O I
10.1002/cyto.990110314
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
It has recently been shown that bimodal histograms with false aneuploid peaks may be obtained by DNA flow cytometry from histologically normal tissue allowed to autolyze. To investigate if such peaks can be generated from surgically excised archival tissue, 198 paraffin blocks from 179 patients containing histologically normal spleen (n = 65), liver (n = 26), thyroid (n = 32), pancreas (n = 19), salivary gland (n = 49), or lymph node tissue (n = 7), obtained from the archives of two university pathology departments, were analyzed for nuclear DNA content. The great majority (n = 160, 83.8%) of the 191 interpretable histograms had a single symmetrical G1 peak; and 8 histograms, all produced from liver tissue had a tetraploid pattern. A slight or a prominent repeatable deviation in the G1 peak outline was present in 14 (7.3%) cases. A peak resembling an aneuploid G1 peak with a DNA index (DI) ranging from 1.14 to 1.38 was repeatedly produced from 9 (4.7%) blocks containing histologically normal or inflamed splenic (n = 3), pancreatc (n = 3), liver (n = 1), thyroid (n = 1), or lymph node (n = 1) tissue. The three abnormal peaks produced from pancreatic tissue were rounded in shape and resembled closely the ones that can be obtained from autolytic pancreatic tissue, and the six remaining extra peaks were all fused with the “diploid” peak. In conclusion, false peaks, probably caused by degradation of the nuclear contents during formalin fixation or before it, may rarely be obtained from surgical paraffin‐embedded samples. Copyright © 1990 Wiley‐Liss, Inc.
引用
收藏
页码:431 / 437
页数:7
相关论文
共 9 条
[1]   AUTOLYSIS IS A POTENTIAL SOURCE OF FALSE ANEUPLOID PEAKS IN FLOW CYTOMETRIC DNA HISTOGRAMS [J].
ALANEN, KA ;
JOENSUU, H ;
KLEMI, PJ .
CYTOMETRY, 1989, 10 (04) :417-425
[2]  
ALANEN KA, 1988, CYTOMETRY, V10, P81
[3]   CELLULAR DNA CONTENT AS A MARKER OF NEOPLASIA IN MAN [J].
BARLOGIE, B ;
DREWINKO, B ;
SCHUMANN, J ;
GOHDE, W ;
DOSIK, G ;
LATREILLE, J ;
JOHNSTON, DA ;
FREIREICH, EJ .
AMERICAN JOURNAL OF MEDICINE, 1980, 69 (02) :195-203
[4]   MEASUREMENT OF S-PHASE FRACTIONS IN LYMPHOID-TISSUE COMPARING FRESH VERSUS PARAFFIN-EMBEDDED TISSUE AND 4',6'-DIAMIDINO-2 PHENYLINDOLE DIHYDROCHLORIDE VERSUS PROPIDIUM IODIDE STAINING [J].
CAMPLEJOHN, RS ;
MACARTNEY, JC ;
MORRIS, RW .
CYTOMETRY, 1989, 10 (04) :410-416
[5]   PITFALLS IN THE PREPARATION OF NUCLEAR SUSPENSIONS FROM PARAFFIN-EMBEDDED TISSUE FOR FLOW-CYTOMETRY [J].
FEICHTER, GE ;
GOERTTLER, K .
CYTOMETRY, 1986, 7 (06) :616-616
[6]   FLOW-CYTOMETRY USING PARAFFIN-EMBEDDED TISSUE - 5 YEARS ON [J].
HEDLEY, DW .
CYTOMETRY, 1989, 10 (03) :229-241
[7]   METHOD FOR ANALYSIS OF CELLULAR DNA CONTENT OF PARAFFIN-EMBEDDED PATHOLOGICAL MATERIAL USING FLOW-CYTOMETRY [J].
HEDLEY, DW ;
FRIEDLANDER, ML ;
TAYLOR, IW ;
RUGG, CA ;
MUSGROVE, EA .
JOURNAL OF HISTOCHEMISTRY & CYTOCHEMISTRY, 1983, 31 (11) :1333-1335
[8]   DIFFERENT OPINIONS ON CLASSIFICATION OF DNA HISTOGRAMS PRODUCED FROM PARAFFIN-EMBEDDED TISSUE [J].
JOENSUU, H ;
KALLIONIEMI, OP .
CYTOMETRY, 1989, 10 (06) :711-717
[9]   A DETERGENT-TRYPSIN METHOD FOR THE PREPARATION OF NUCLEI FOR FLOW CYTOMETRIC DNA ANALYSIS [J].
VINDELOV, LL ;
CHRISTENSEN, IJ ;
NISSEN, NI .
CYTOMETRY, 1983, 3 (05) :323-327