THE TRANSFER OF TRICHLOROETHYLENE (TCE) FROM A SHOWER TO INDOOR AIR - EXPERIMENTAL MEASUREMENTS AND THEIR IMPLICATIONS

被引:26
作者
MCKONE, TE
KNEZOVICH, JP
机构
[1] University of California, Lawrence Livermore National Laboratory Livermore, CA
来源
JOURNAL OF THE AIR & WASTE MANAGEMENT ASSOCIATION | 1991年 / 41卷 / 06期
关键词
D O I
10.1080/10473289.1991.10466881
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Experiments were performed to measure the transfer of trichloroethylene (TCE), a volatile organic compound (VOC), from tap water in showers to indoor air. In these experiments, the loss of TCE from tap water In the shower is based on the difference between influent and effluent concentrations. We have developed and previously published a three-compartment model, which we use to simulate the 24-h concentration history of VOCs In the shower, bathroom, and remaining household volumes resulting from the use of contaminated tap water. An important input to this model is the transfer efficiency of the VOC from water to air. The experiments reveal that the transfer efficiency of TCE from shower water to air has an arithmetic mean value of 61 percent and an arithmetic standard deviation of 9 percent. Analysis of the results shows that there is no statistically significant difference between the transfer efficiency measured with hot (37-degrees-C) or cold (22-degrees-C) shower water and that there is no statistically significant change in transfer efficiency with time during a 20-min shower. The implications for exposure assessment are considered.
引用
收藏
页码:832 / 837
页数:6
相关论文
共 15 条
[1]   INHALATION EXPOSURE IN THE HOME TO VOLATILE ORGANIC CONTAMINANTS OF DRINKING-WATER [J].
ANDELMAN, JB .
SCIENCE OF THE TOTAL ENVIRONMENT, 1985, 47 (DEC) :443-460
[2]   HUMAN EXPOSURES TO VOLATILE HALOGENATED ORGANIC-CHEMICALS IN INDOOR AND OUTDOOR AIR [J].
ANDELMAN, JB .
ENVIRONMENTAL HEALTH PERSPECTIVES, 1985, 62 (OCT) :313-318
[3]  
COTHERN R, 1984, PB84213941
[4]  
FISH WJ, 1987, INDOOR AIR QUALITY C
[5]  
Hess C.T., 1982, ENVIRON INT, V8, P59
[6]  
Lyman W. J., 1982, HDB CHEM PROPERTY ES
[7]   FUGACITY MODELS OF INDOOR EXPOSURE TO VOLATILE CHEMICALS [J].
MACKAY, D ;
PATERSON, S .
CHEMOSPHERE, 1983, 12 (02) :143-154
[8]   HUMAN EXPOSURE TO VOLATILE ORGANIC-COMPOUNDS IN HOUSEHOLD TAP WATER - THE INDOOR INHALATION PATHWAY [J].
MCKONE, TE .
ENVIRONMENTAL SCIENCE & TECHNOLOGY, 1987, 21 (12) :1194-1201
[9]   POTABLE WATER AS A SOURCE OF AIRBORNE RN-222 IN UNITED-STATES DWELLINGS - A REVIEW AND ASSESSMENT [J].
NAZAROFF, WW ;
DOYLE, SM ;
NERO, AV ;
SEXTRO, RG .
HEALTH PHYSICS, 1987, 52 (03) :281-295
[10]   AN ESTIMATE OF POPULATION EXPOSURES DUE TO RADON IN PUBLIC WATER-SUPPLIES IN THE AREA OF HOUSTON, TEXAS [J].
PRICHARD, HM ;
GESELL, TF .
HEALTH PHYSICS, 1981, 41 (04) :599-606