SPIRAL GRADIENT END-POINT METHOD COMPARED TO STANDARD AGAR DILUTION FOR SUSCEPTIBILITY TESTING OF ANAEROBIC GRAM-NEGATIVE BACILLI

被引:5
作者
HILL, GB
机构
[1] DUKE UNIV,MED CTR,ANAEROBE SECT,CLIN MICROBIOL LAB,DURHAM,NC 27710
[2] DUKE UNIV,MED CTR,DEPT MICROBIOL & IMMUNOL,DURHAM,NC 27710
关键词
D O I
10.1128/JCM.29.5.975-979.1991
中图分类号
Q93 [微生物学];
学科分类号
071005 ; 100705 ;
摘要
More efficient and reproducible alternative methods of performing agar dilution susceptibility testing are desirable, particularly for anaerobic bacteria. Anaerobes generally grow more reliably on solid media than they do in broth microdilution wells. A new method, the revised spiral gradient endpoint (SGE) method, was evaluated against the standard agar dilution (SAD) method by using a wide variety of anaerobic gram-negative bacilli (161 strains) and eight antimicrobial agents. For the SGE method, a spiral plater was used to set up a concentration gradient of an antimicrobial agent within an agar plate across which bacterial strains were inoculated as radial streaks. After incubation, the MIC of the antimicrobial agent was calculated from the radial endpoint location where bacterial growth ceased along the streak. The MICs for 90% of strains tested (in micrograms per milliliter) and the cumulative percentages of susceptible strains at the breakpoints for the SGE and SAD methods, respectively, and for all 161 strains were as follows: for metronidazole, 2 and 100 versus 2 and 100; for imipenem, 1 and 99 versus 0.5 and 98; for ampicillin-sulbactam, 8 and 97 versus 8 and 98; for clindamycin, 4 and 90 versus 4 and 91; for cefoxitin, 32 and 95 versus 32 and 95; for mezlocillin, 256 and 88 versus > 128 and 86; for ampicillin, greater-than-or-equal-to 256 and 51 versus > 64 and 51; and for penicillin (in units per milliliter), greater-than-or-equal-to 512 and 71 versus > 64 and 65. The excellent agreement of these data and the greater sensitivity, reproducibility, and efficiency of the revised SGE method warrant further evaluations. Assuming that these advantages are confirmed, the revised SGE method should be a useful alternative test method when detailed susceptibility data are desired.
引用
收藏
页码:975 / 979
页数:5
相关论文
共 16 条
[1]   NATIONAL-COMMITTEE-FOR-CLINICAL-LABORATORY-STANDARDS AGAR DILUTION SUSCEPTIBILITY TESTING OF ANAEROBIC GRAM-NEGATIVE BACTERIA [J].
BROWN, WJ .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1988, 32 (03) :385-390
[2]   THE ANTIMICROBIAL SUSCEPTIBILITY PATTERNS OF THE BACTEROIDES-FRAGILIS GROUP IN THE UNITED-STATES, 1987 [J].
CORNICK, NA ;
CUCHURAL, GJ ;
SNYDMAN, DR ;
JACOBUS, NV ;
IANNINI, P ;
HILL, G ;
CLEARY, T ;
OKEEFE, JP ;
PIERSON, C ;
FINEGOLD, SM .
JOURNAL OF ANTIMICROBIAL CHEMOTHERAPY, 1990, 25 (06) :1011-1019
[3]  
CUCHURAL G, 1987, 27TH INT C ANT AG CH
[4]   SUSCEPTIBILITY TESTING OF ANAEROBIC-BACTERIA [J].
FINEGOLD, SM .
JOURNAL OF CLINICAL MICROBIOLOGY, 1988, 26 (07) :1253-1256
[6]  
HILL GB, 1990, REV INFECT DIS, V12, pS200
[7]  
HINDLE M, 1987, P S SPIRAL SYSTEM AN, P3
[8]  
MOLITORIS E, 1990, 1990 ANN M AM SOC MI, P387
[9]   ACTIVITY OF NEWER BETA-LACTAM AGENTS AGAINST CLINICAL ISOLATES OF BACTEROIDES-FRAGILIS AND OTHER BACTEROIDES SPECIES [J].
OKEEFE, JP ;
VENEZIO, FR ;
DIVINCENZO, CA ;
SHATZER, KL .
ANTIMICROBIAL AGENTS AND CHEMOTHERAPY, 1987, 31 (12) :2002-2004
[10]  
SCHALKOWSKY S, 1985, PRELIMINARY USER GUI