BALLOON ANGIOPLASTY-BRANCH PULMONARY-ARTERY STENOSIS - RESULTS FROM THE VALVULOPLASTY AND ANGIOPLASTY OF CONGENITAL-ANOMALIES REGISTRY

被引:77
作者
KAN, JS
MARVIN, WJ
BASS, JL
MUSTER, AJ
MURPHY, J
机构
[1] UNIV IOWA HOSP & CLIN,IOWA CITY,IA 52242
[2] CHILDRENS MEM HOSP,CHICAGO,IL 60614
[3] UNIV MINNESOTA HOSP & CLIN,MINNEAPOLIS,MN 55455
[4] CHILDRENS HOSP PHILADELPHIA,PHILADELPHIA,PA
关键词
D O I
10.1016/0002-9149(90)91391-I
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Balloon angioplasty for branch pulmonary artery stenosis was reported from 27 institutions to the Valvuloplasty and Angioplasty of Congenital Anomalies Registry. One hundred eighty-two procedures were performed in 156 patients ranging in age from 0.2 to 46.2 years (mean 7.7). Short-term angiographic appearance, hemodynamic results and immediate complications were recorded. Vessel dimension at the site of stenosis increased from 4.5 ± 2.0 (mean ± standard deviation) to 6.8 ± 3.0 mm (p < 0.001) with greater increases in vessel dimension at the site of stenosis if the balloon diameter was >3 X the original dimension of the stenosis. There was no significant benefit related to age or prior surgical intervention. The mean peak systolic pressure gradient was reduced from 49 ± 25 to 37 ± 26 mm Hg (p < 0.001) and pressure proximal to the stenosis decreased from 69 ± 25 to 63 ± 24 mm Hg (p < 0.001). Complications occurred in 21 patients and included vessel rupture and death in 2 patients, vessel perforation or rupture with survival in 3, cardiac arrest and death in 1, paradoxical embolism and death in 1 and low output and death in 1. Balloon angioplasty for branch pulmonary artery stenosis increases vessel dimension at the site of stenosis, reduces systolic pressure gradient and to a minor degree, reduces proximal pressure. Long-term outcome and potential complications are as yet uncertain. © 1990.
引用
收藏
页码:798 / 801
页数:4
相关论文
共 11 条
  • [1] CONGENITAL STENOSIS OF PULMONARY ARTERY BRANCHES
    BAUM, D
    ONGLEY, PA
    KINCAID, OW
    KHOURY, GH
    SWAN, HJC
    [J]. CIRCULATION, 1964, 29 (05) : 680 - &
  • [2] SUCCESSFUL BALLOON ANGIOPLASTY OF PERIPHERAL PULMONARY STENOSIS IN WILLIAMS SYNDROME
    DORSOGNA, L
    SANDOR, GGS
    CULHAM, JAG
    [J]. AMERICAN HEART JOURNAL, 1987, 114 (03) : 647 - 648
  • [3] MORPHOLOGIC CHANGES IN THE PULMONARY-ARTERIES AFTER PERCUTANEOUS BALLOON ANGIOPLASTY FOR PULMONARY ARTERIAL-STENOSIS
    EDWARDS, BS
    LUCAS, RV
    LOCK, JE
    EDWARDS, JE
    [J]. CIRCULATION, 1985, 71 (02) : 195 - 201
  • [4] PULMONARY ARTERY STENOSIS ASSOCIATED WITH DUCTUS ARTERIOSUS FOLLOWING MATERNAL RUBELLA
    EMMANOUILIDES, GC
    CRITTENDEN, IH
    LINDE, LM
    [J]. CIRCULATION, 1964, 29 (04) : 514 - &
  • [5] GILL CC, 1977, J THORAC CARDIOV SUR, V73, P436
  • [6] HAWORTH SG, 1981, BRIT HEART J, V45, P133
  • [7] TRANSVENOUS ANGIOPLASTY OF EXPERIMENTAL BRANCH PULMONARY-ARTERY STENOSIS IN NEWBORN LAMBS
    LOCK, JE
    NIEMI, T
    EINZIG, S
    AMPLATZ, K
    BURKE, B
    BASS, JL
    [J]. CIRCULATION, 1981, 64 (05) : 886 - 893
  • [8] BALLOON DILATION ANGIOPLASTY OF HYPOPLASTIC AND STENOTIC PULMONARY-ARTERIES
    LOCK, JE
    CASTANEDAZUNIGA, WR
    FUHRMAN, BP
    BASS, JL
    [J]. CIRCULATION, 1983, 67 (05) : 962 - 967
  • [9] MCGOON DC, 1964, MED CLIN N AM, V487, P1083
  • [10] RING JC, 1985, J THORAC CARDIOV SUR, V90, P35