REDUCED LEFT-VENTRICULAR COMPLIANCE IN HUMAN MITRAL-STENOSIS - ROLE OF REVERSIBLE INTERNAL CONSTRAINT

被引:74
作者
LIU, CP
TING, CT
YANG, TM
CHEN, JW
CHANG, MS
MAUGHAN, WL
LAWRENCE, W
KASS, DA
机构
[1] VET GEN HOSP,DIV CARDIOL,TAIPEI,TAIWAN
[2] JOHNS HOPKINS MED INST,DEPT INTERNAL MED,DIV CARDIOL,BALTIMORE,MD 21205
关键词
VALVES; VENTRICULAR FUNCTION; VALVULOPLASTY; DIASTOLE; SYSTOLE; PRESSURE-VOLUME RELATION;
D O I
10.1161/01.CIR.85.4.1447
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. The mechanisms of depressed left ventricular (LV) pump performance in human mitral stenosis (MS) remain poorly understood, because reduced filling alone affects many hemodynamic measurements. Therefore, pressure-volume relations were examined in nine subjects with MS and compared with eight age-matched normal controls. Methods and Results. Data were obtained by conductance catheter/micromanometer technique with transient inferior vena cava occlusion used to alter load and generate pressure-volume relations. In a subset of patients (n = 5), data were obtained both acutely and at 3 months (n = 4) after balloon valvuloplasty. MS patients had reduced cardiac output (3.3 +/- 0.9 versus 5.6 +/- 1.7 l/min) and end-diastolic volume (68.0 +/- 6.9 versus 115 +/- 31 ml) versus controls (p < 0.001), with a mean transvalvular gradient of 14 +/- 6 mm Hg and estimated valve area of 0.6 +/- 0.2 cm2. Systolic function as assessed by the end-systolic pressure-volume relation was virtually the same in MS and control subjects. In contrast, end-diastolic pressure-volume relations in MS were consistently shifted leftward and had an increased slope (lower compliance) at matched pressure ranges (6.5 +/- 3.0 versus 2.2 +/- 0.53 ml/mm Hg at a mean diastolic pressure of 8 mm Hg, p < 0.001). This change was not a result of reduced LV filling or probably of increased right heart loading. Valvuloplasty acutely returned chamber compliance to near normal, a change that was sustained at 3-month follow-up. Systolic function was little altered at this time. Conclusions. These data indicate an impairment of diastolic function in human MS that can be acutely reversed by balloon valvuloplasty. Lowered LV compliance probably results from a functional restriction caused by ventricular attachment to a thickened and immobile valve apparatus.
引用
收藏
页码:1447 / 1456
页数:10
相关论文
共 27 条
[1]   STATE OF LEFT-VENTRICULAR MYOCARDIUM IN MITRAL-STENOSIS [J].
AHMED, SS ;
REGAN, TJ ;
FIORE, JJ ;
LEVINSON, GE .
AMERICAN HEART JOURNAL, 1977, 94 (01) :28-36
[2]   ANALYSIS OF LEFT-VENTRICULAR FUNCTION IN RESPONSE TO AFTERLOAD CHANGES IN PATIENTS WITH MITRAL-STENOSIS [J].
BOLEN, JL ;
LOPES, MG ;
HARRISON, DC ;
ALDERMAN, EL .
CIRCULATION, 1975, 52 (05) :894-900
[3]  
CHANG MS, 1988, CHIN MED J TAIPEI, V42, P7
[4]  
CURRY GC, 1972, AM J CARDIOL, V29, P621, DOI 10.1016/0002-9149(72)90162-2
[5]   EVALUATION OF LEFT VENTRICLE IN PATIENTS WITH MITRAL STENOSIS [J].
FEIGENBAUM, H ;
CAMPBELL, RW ;
WUNSCH, CM ;
STEINMETZ, EF .
CIRCULATION, 1966, 34 (03) :462-+
[6]  
FLEMING HA, 1959, BRIT HEART J, V2, P117
[7]   LEFT-VENTRICULAR EJECTION PERFORMANCE AND SYSTOLIC MUSCLE FUNCTION IN PATIENTS WITH MITRAL-STENOSIS [J].
GASH, AK ;
CARABELLO, BA ;
CEPIN, D ;
SPANN, JF .
CIRCULATION, 1983, 67 (01) :148-154
[8]  
Glantz SA, 1990, PRIMER APPL REGRESSI, P381
[9]   LINEARITY OF THE FRANK-STARLING RELATIONSHIP IN THE INTACT HEART - THE CONCEPT OF PRELOAD RECRUITABLE STROKE WORK [J].
GLOWER, DD ;
SPRATT, JA ;
SNOW, ND ;
KABAS, JS ;
DAVIS, JW ;
OLSEN, CO ;
TYSON, GS ;
SABISTON, DC ;
RANKIN, JS .
CIRCULATION, 1985, 71 (05) :994-1009
[10]  
HANSEN DE, 1989, J THORAC CARDIOV SUR, V97, P521