UNUSUAL PD PULSE PHASE DISTRIBUTIONS IN OPERATING ROTATING MACHINES

被引:22
作者
STONE, GC
GOODEVE, TE
SEDDING, HG
MCDERMID, W
机构
[1] ONTARIO HYDRO TECHNOL,TORONTO,ON,CANADA
[2] MANITOBA HYDRO,WINNIPEG,MB,CANADA
关键词
D O I
10.1109/94.407022
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The position of partial discharges (PD) with respect to power frequency phase position has long been known to provide useful information on the nature of deterioration of electrical insulation. In the past, virtually all such data has been from PD tests performed in the laboratory on static models or equipment. Improvements in the past 15 years in noise elimination technology have made it possible to monitor the PD activity (number, magnitude and phase position) in the HV stator windings of operating motors and generators. Over a two year period, the PD activity was recorded on more than 100 motors, hydrogenerators and turbine generators, and the pulses analyzed with respect to the ac phase position, with a resolution of 3.6 degrees. In the majority of stator windings, the PD pulses occurred in the expected portion of the ac phase, i.e. between 0 and 90 degrees as well as between 180 and 270 degrees. However a significant number of instances were recorded where the pulses appeared to be shifted similar to 30 degrees. This is probably due to the phase-to-phase electric stress which occurs in the endwinding portion of a three phase stator winding. In many other machines, the PD phase positions were very different from the expected patterns determined from static tests. In some of these cases, such results were obtained on machines with suspected loose stator windings. It seems reasonable to conclude that the unusual PD patterns may be due to the influence of moving stator coils on the PD patterns. Such an influence is not easy to simulate in static laboratory tests. PD pulse phase analysis is shown to be a useful means of helping to determine the main deterioration mechanisms of stator insulation systems of operating motors and generators.
引用
收藏
页码:567 / 577
页数:11
相关论文
共 18 条
[1]  
Bartnikas R., 1979, ASTM PUBLICATION, V669
[2]  
Bartnikas R., 1969, IEEE T INSTRUMENTATI, VIM-18, P403
[3]  
CAMPBELL SR, 1994, IEEE T EC JUN, P281
[4]  
CIGRE Working Group 21.03, 1969, ELECTRA, V11, P61
[5]  
GRUNEWALD P, 1994, CIGRE11206 PAP
[6]  
HOZUMI N, 1991, 3RD P INT C PROP APP, P47
[7]  
JOHNSON J, 1951, T AIEE 2, P1993
[8]  
KELEN A, 1976, CIGRE1503 PAP
[9]   ASSESSMENT OF DETERIORATION IN EPOXY MICA MACHINE INSULATION [J].
KIM, YJ ;
NELSON, JK .
IEEE TRANSACTIONS ON ELECTRICAL INSULATION, 1992, 27 (05) :1026-1039
[10]   APPLICATION OF PARTIAL DISCHARGE TESTING TO HYDRO GENERATOR MAINTENANCE [J].
KURTZ, M ;
LYLES, JF ;
STONE, GC .
IEEE TRANSACTIONS ON POWER APPARATUS AND SYSTEMS, 1984, 103 (08) :2148-2157