BATCH SQUARE-WAVE VOLTAMMETRIC AND FLOW-INJECTION AMPEROMETRIC DETERMINATION OF TRACE AMOUNTS OF BROMOFENOXIM

被引:8
作者
CAI, XH
OGOREVC, B
BENFENATI, E
KALCHER, K
NOVIC, M
GRABEC, I
机构
[1] NATL INST CHEM,ANALYT CHEM LAB,LJUBLJANA 61115,SLOVENIA
[2] IST RIC FARMACOL MARIO NEGRI,MILAN,ITALY
[3] GRAZ UNIV,INST ANALYT CHEM,GRAZ,AUSTRIA
关键词
AMPEROMETRY; VOLTAMMETRY; FLOW INJECTION; BROMOFENOXIM; HERBICIDES;
D O I
10.1016/0003-2670(95)00105-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Two sensitive and rapid methods, batch voltammetric and flow- injection analysis (FIA) with amperometric detection are reported, for trace determination of the herbicide bromofenoxim. Preliminary results on its electrochemical behaviour are presented as well. While bromofenoxim did not exhibit any response at bare solid electrodes, two well-defined voltammetric reduction peaks were obtained at mercury electrodes. Both peaks, with peak potentials at -0.38 V and -0.54 V vs. Ag/AgCl in pH 7 Britton-Robinson buffer, appear as a consequence of a reduction of the two nitro groups of bromofenoxim, and show strong adsorption nature. The first peak, at the less negative potential, was found to be more sensitive and was therefore utilised for the voltammetric determination of bromofenoxim. In direct batch voltammetric analysis at a dropping mercury electrode by applying square-wave voltammetry (SWV), linearity between SWV signal and bromofenoxim concentration was found to exist from 0.5 mu g/l to 600 mu g/l(1.1 X 10(-9) mol/l to 1.3 X 10(-6) mol/l), with an estimated limit of detection of 0.1 mu g/l. Dynamic properties and in situ formation of the mercury film coated glassy carbon electrodes were also investigated for the determination of bromofenoxim in flow- injection systems. Employing FIA with amperometric detection at an operating potential of -0.7 V vs. Ag/AgCl, the signal response was linearly dependent on the bromofenoxim concentration within the range from 50 mu g/l to 4000 mu g/l (1.1 X 10(-7) mol/l to 0.9 X 10(-5) mol/l) and a detection limit (3(sigma)) of 10 mu g/l (0.4 ng absolute, 40 mu l) was obtained. Optimisation of parameters for the amperometric detection of bromofenoxim and utilisation of the proposed methods are presented and discussed.
引用
收藏
页码:153 / 160
页数:8
相关论文
共 13 条
[1]   DETERMINATION OF PHENOLIC HERBICIDES IN SOIL BY PEROXYOXALATE CHEMILUMINESCENCE [J].
ABUBAKER, MA ;
VONWANDRUSZKA, R .
ANALYTICAL LETTERS, 1991, 24 (01) :93-102
[2]   APPLIED POLAROGRAPHY AND VOLTAMMETRY OF ORGANIC-COMPOUNDS IN PRACTICAL DAY-TO-DAY ANALYSIS .2. [J].
BERSIER, PM ;
BERSIER, J .
CRC CRITICAL REVIEWS IN ANALYTICAL CHEMISTRY, 1985, 16 (02) :81-128
[3]   SQUARE-WAVE ADSORPTIVE STRIPPING VOLTAMMETRY ON MERCURY FILM ELECTRODES [J].
ECONOMOU, A ;
FIELDEN, PR .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :27-34
[4]  
EISERT R, 1994, IN PRESS INT J ENV A
[5]  
FIELDING M, 1992, 27 COMM EUR COMM WAT
[6]   MERCURY FILMS ON A GLASSY-CARBON SUPPORT - ATTRIBUTES AND PROBLEMS [J].
FRENZEL, W .
ANALYTICA CHIMICA ACTA, 1993, 273 (1-2) :123-137
[7]   DETERMINATION OF PARAQUAT BY CATHODIC STRIPPING VOLTAMMETRY AFTER ACCUMULATION THROUGH THE FORMATION OF AN ION-PAIR ON A HANGING MERCURY DROP ELECTRODE [J].
MACIAS, JMP ;
HERNANDEZ, LH ;
SOBRINO, JMM ;
ESCRIBANO, MTS .
ELECTROANALYSIS, 1993, 5 (01) :79-83
[8]  
MOLLA MTO, 1993, 4TH WORKSH CHEM FAT, P13
[9]  
ROVIDA C, 1994, UNPUB TOXICOL ENV CH
[10]  
SMYTH MR, 1978, ANALYST, V103, P529, DOI 10.1039/an9780300529