ELECTROCARDIOGRAPHIC IDENTIFICATION OF INCREASED LEFT-VENTRICULAR MASS BY SIMPLE VOLTAGE-DURATION PRODUCTS

被引:323
作者
OKIN, PM
ROMAN, MJ
DEVEREUX, RB
KLIGFIELD, P
机构
[1] Division of Cardiology, Department of Medicine, The New York Hospital-Cornell Medical Center, New York, NY
关键词
D O I
10.1016/0735-1097(94)00371-V
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objectives. This study was conducted to validate the hypothesis that the product of QRS voltage and duration, as an approximation of the time-voltage area of the QRS complex, can improve the electrocardiographic (ECG) detection of echocardiographically determined left ventricular hypertrophy and to further assess the relative contribution of QRS duration to the ECG detection of hypertrophy. Background. The ECG identification of left ventricular hypertrophy has been limited by the poor sensitivity of standard voltage criteria alone. However, increases in left ventricular mass can be more accurately related to increases in the time-voltage area of the QRS complex than to changes in QRS voltage or duration alone. Methods. Standard 12-lead ECGs and echocardiograms were obtained for 389 patients, including 116 patients with left ventricular hypertrophy. Simple voltage-duration products were calculated by multiplying Cornell voltage by QRS duration (Cornell product) and the 12-lead sum of voltage by QRS duration (12-lead product). Results. In a stepwise logistic regression model that also included Cornell voltage, Sokolow-Lyon voltage, age and gender, QRS duration remained a highly significant predictor of the presence of left ventricular hypertrophy (chi square 26.9, p < 0.0001). At a matched specificity of 96%, each voltage-duration product significantly improved sensitivity for the detection of left ventricular hypertrophy compared with simple voltage criteria alone (Cornell product 37% vs. Cornell voltage 28%, p < 0.02, and 12-lead product 50% vs. 12-lead voltage 43%, p < 0.005). Sensitivities of both the Cornell product and the 12-lead product were significantly greater than the 27% sensitivity of QRS duration alone (p < 0.01 vs. p < 0.001), the 20% sensitivity of a Romhilt-Estes point score >4 (p < 0.001) and the 33% sensitivity of the best-fit logistic regression model in this cohort (p < 0.05 vs. p < 0.001). Conclusions. QRS duration is an independent ECG predictor of the presence of left ventricular hypertrophy, and the simple product of either Cornell voltage or 12 lead voltage and QRS duration significantly improves identification of left ventricular hypertrophy relative to other ECG criteria that use QRS duration and voltages in linear combinations.
引用
收藏
页码:417 / 423
页数:7
相关论文
共 42 条
  • [1] IMPROVED SEX-SPECIFIC CRITERIA OF LEFT-VENTRICULAR HYPERTROPHY FOR CLINICAL AND COMPUTER INTERPRETATION OF ELECTROCARDIOGRAMS - VALIDATION WITH AUTOPSY FINDINGS
    CASALE, PN
    DEVEREUX, RB
    ALONSO, DR
    CAMPO, E
    KLIGFIELD, P
    [J]. CIRCULATION, 1987, 75 (03) : 565 - 572
  • [2] ELECTROCARDIOGRAPHIC DETECTION OF LEFT-VENTRICULAR HYPERTROPHY - DEVELOPMENT AND PROSPECTIVE VALIDATION OF IMPROVED CRITERIA
    CASALE, PN
    DEVEREUX, RB
    KLIGFIELD, P
    EISENBERG, RR
    MILLER, DH
    CHAUDHARY, BS
    PHILLIPS, MC
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1985, 6 (03) : 572 - 580
  • [3] VALUE OF ECHOCARDIOGRAPHIC MEASUREMENT OF LEFT-VENTRICULAR MASS IN PREDICTING CARDIOVASCULAR MORBID EVENTS IN HYPERTENSIVE MEN
    CASALE, PN
    DEVEREUX, RB
    MILNER, M
    ZULLO, G
    HARSHFIELD, GA
    PICKERING, TG
    LARAGH, JH
    [J]. ANNALS OF INTERNAL MEDICINE, 1986, 105 (02) : 173 - 178
  • [4] ECHOCARDIOGRAPHIC ASSESSMENT OF LEFT-VENTRICULAR HYPERTROPHY - COMPARISON TO NECROPSY FINDINGS
    DEVEREUX, RB
    ALONSO, DR
    LUTAS, EM
    GOTTLIEB, GJ
    CAMPO, E
    SACHS, I
    REICHEK, N
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1986, 57 (06) : 450 - 458
  • [5] DEVEREUX RB, 1987, HYPERTENSION, V9, P69
  • [6] DEVEREUX RB, 1983, J AM COLL CARDIOL, V2, P82
  • [7] PERFORMANCE OF CONVENTIONAL ORTHOGONAL AND MULTIPLE-DIPOLE ELECTROCARDIOGRAMS IN ESTIMATING LEFT-VENTRICULAR MUSCLE MASS
    DUNN, RA
    PIPBERGER, HV
    HOLT, JH
    BARNARD, ACL
    PIPBERGER, HA
    [J]. CIRCULATION, 1979, 60 (06) : 1350 - 1353
  • [8] MECHANISMS OF QRS COMPLEX PROLONGATION IN MAN - LEFT VENTRICULAR CONDUCTION DISTURBANCES
    GRANT, RP
    DODGE, HT
    [J]. AMERICAN JOURNAL OF MEDICINE, 1956, 20 (06) : 834 - 852
  • [9] Electrocardiographic criteria of left ventricular hypertrophy - Factors determining the evolution of the electrocardiographic patterns in hypertrophy and bundle branch block
    Gubner, R
    Ungerleider, HE
    [J]. ARCHIVES OF INTERNAL MEDICINE, 1943, 72 (02) : 196 - 209
  • [10] THE PREVALENCE AND CORRELATES OF ECHOCARDIOGRAPHIC LEFT-VENTRICULAR HYPERTROPHY AMONG EMPLOYED PATIENTS WITH UNCOMPLICATED HYPERTENSION
    HAMMOND, IW
    DEVEREUX, RB
    ALDERMAN, MH
    LUTAS, EM
    SPITZER, MC
    CROWLEY, JS
    LARAGH, JH
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1986, 7 (03) : 639 - 650