X-RAY-FLUORESCENCE MEASUREMENTS OF LEAD BURDEN IN SUBJECTS WITH LOW-LEVEL COMMUNITY LEAD-EXPOSURE

被引:83
作者
HU, H
MILDER, FL
BURGER, DE
机构
[1] HARVARD UNIV,SCH PUBL HLTH,DEPT EPIDEMIOL,OCCUPAT HLTH PROGRAM,BOSTON,MA 02115
[2] ABIOMED INC,DANVERS,MA
来源
ARCHIVES OF ENVIRONMENTAL HEALTH | 1990年 / 45卷 / 06期
关键词
D O I
10.1080/00039896.1990.10118752
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
A k-x-ray fluorescence (K-XRF) instrument that can measure in vivo bone lead at low levels was used on a population of 34 adults with no known history of excessive lead exposure. A questionnaire that gathered information relevant to occupational and environmental lead exposure was administered prior to the measurement. A 30-min measurement that produced an average estimated uncertainty of 6 mcg lead/g bone mineral was taken at the mid-tibial diaphysis for each subject. Eighteen subjects had bone lead levels below the measurement uncertainty. The remainder had bone lead levels ranging up to 21 mcg lead/g bone mineral. Bone lead levels were greater among older subjects. Among young adult subjects, bone lead levels greater than the measurement uncertainty were confined entirely to subjects who had grown up in housing that was estimated to have been built prior to 1955. Such a childhood environment is at high risk of fostering exposure to biologically absorbable lead through ingestion of lead paint-contaminated dust and lead pipe-contaminated water. We conclude that the K-XRF technique has the potential to distinguish between low levels of lead burden in epidemiologic studies.
引用
收藏
页码:335 / 341
页数:7
相关论文
共 23 条
[1]  
[Anonymous], 1988, NATURE EXTENT LEAD P
[2]  
BARRY PSI, 1970, BRIT J IND MED, V27, P339
[3]  
BARRY PSI, 1975, BRIT J IND MED, V32, P119
[4]   CONTRIBUTION OF LEAD TO HYPERTENSION WITH RENAL IMPAIRMENT [J].
BATUMAN, V ;
LANDY, E ;
MAESAKA, JK ;
WEDEEN, RP .
NEW ENGLAND JOURNAL OF MEDICINE, 1983, 309 (01) :17-21
[5]   LONGITUDINAL ANALYSES OF PRENATAL AND POSTNATAL LEAD-EXPOSURE AND EARLY COGNITIVE-DEVELOPMENT [J].
BELLINGER, D ;
LEVITON, A ;
WATERNAUX, C ;
NEEDLEMAN, H ;
RABINOWITZ, M .
NEW ENGLAND JOURNAL OF MEDICINE, 1987, 316 (17) :1037-1043
[6]  
BURGER DE, IN PRESS 2ND P INT S
[7]   LEAD IN HUMAN TISSUES [J].
GROSS, SB ;
PFITZER, EA ;
YEAGER, DW ;
KEHOE, RA .
TOXICOLOGY AND APPLIED PHARMACOLOGY, 1975, 32 (03) :638-651
[8]   BLOOD LEAD AND BLOOD-PRESSURE - RELATIONSHIP IN THE ADOLESCENT AND ADULT UNITED-STATES POPULATION [J].
HARLAN, WR ;
LANDIS, JR ;
SCHMOUDER, RL ;
GOLDSTEIN, NG ;
HARLAN, LC .
JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 1985, 253 (04) :530-534
[9]   X-RAY-FLUORESCENCE - ISSUES SURROUNDING THE APPLICATION OF A NEW TOOL FOR MEASURING BURDEN OF LEAD [J].
HU, H ;
MILDER, FL ;
BURGER, DE .
ENVIRONMENTAL RESEARCH, 1989, 49 (02) :295-317
[10]  
LANDRIGAN PJ, 1989, BRIT J IND MED, V46, P593