APPLICATION OF RADIOACTIVE-TRACERS FOR INVESTIGATION OF DYSPROSIUM AND MANGANESE VAPORIZATION IN ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY

被引:8
作者
CHAUDHRY, MM
LITTLEJOHN, D
WHITLEY, JE
机构
[1] UNIV STRATHCLYDE,DEPT PURE & APPL CHEM,CATHEDRAL ST,GLASGOW G1 1XL,SCOTLAND
[2] SCOTTISH UNIV RES & REACTOR CTR,E KILBRIDE G75 0QU,LANARK,SCOTLAND
关键词
RADIOACTIVE TRACER; WALL; PLATFORM AND PROBE ELECTROTHERMAL ATOMIZATION; ATOMIC ABSORPTION SPECTROMETRY; PYROLYTIC GRAPHITE COATED ELECTROGRAPHITE; TOTAL PYROLYTIC GRAPHITE;
D O I
10.1039/ja9920700029
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Radioactive tracers Dy-165 and Mn-56 have been used to investigate the vaporization of Dy and Mn in a graphite furnace. The retention and distribution of the analytes after atomization in pyrolytic graphite coated electrographite (PCG) tubes have been measured and the efficiencies of Dy and Mn vaporization have been compared for wall, platform and probe atomization in total pyrolytic graphite (TPG) tubes. Manganese is vaporized almost completely (95-100%) at 2500-degrees-C by each of the atomization modes, with little retention at the point of initial deposition. Manganese is redeposited at the very ends of the PCG tube and the amount of redeposition increases with the age of the tube. Total pyrolytic graphite (TPG) exhibits lower redeposition of Mn than does PCG and the deposition is mainly on the outside of the tube. Dysprosium is almost totally retained in PCG and TPG tubes. Vaporized Dy is redeposited very rapidly, mainly at the centre of the tube, and causes a memory effect in subsequent heating cycles. About 60% of the Dy is vaporized from the probe at 2750-degrees-C, whereas only 7% is vaporized from the platform. The difference in the vaporization efficiencies is reflected in the atomic absorption spectrometric sensitivities for both procedures. Wall atomization gives the best sensitivity for Dy, but is only 1.5-fold better than for probe atomization. Some comments are given on the possible mechanisms of Dy vaporization and atomization, but mass spectrometry studies are required to give a clearer explanation of the phenomena.
引用
收藏
页码:29 / 34
页数:6
相关论文
共 18 条
[1]  
BRODIE K, 1982, ANAL METHODS GRAPHIT, pCH2
[2]   PEAK PROFILE AND APPEARANCE TIMES USING TOTALLY PYROLYTIC CUVETTES IN GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
BROWN, AA ;
LEE, M .
FRESENIUS ZEITSCHRIFT FUR ANALYTISCHE CHEMIE, 1986, 323 (07) :697-702
[3]   APPLICATION AND EVALUATION OF AN AUTOMATIC GRAPHITE PROBE ATOMIZER FOR THE CONTROL OF VAPOR-PHASE INTERFERENCES IN ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
CORR, SP ;
LITTLEJOHN, D .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :125-129
[4]   TOTALLY PYROLYTIC-GRAPHITE TUBES IN ELECTROTHERMAL ATOMIZATION ATOMIC-ABSORPTION SPECTROMETRY [J].
DELOOSVOLLEBREGT, MTC ;
BOL, M ;
DEGALAN, L .
JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1988, 3 (01) :151-154
[5]  
DUNCAN IS, 1984, ANAL CHIM ACTA, V157, P291
[6]   A TABLE AND METHOD FOR DETERMINING TRUE TIME REPRESENTING A COUNT RATE OBSERVED IN RADIONUCLEAR COUNTING [J].
HOFFMAN, BW ;
VANCAMER.SB .
ANALYTICAL CHEMISTRY, 1967, 39 (10) :1198-&
[7]   CHEMICAL-REACTIONS IN THE DETERMINATION OF GERMANIUM BY GRAPHITE-FURNACE ATOMIC-ABSORPTION SPECTROMETRY [J].
KOLB, A ;
MULLERVOGT, G ;
WENDL, W ;
STOSSEL, W .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1987, 42 (08) :951-957
[8]  
KRIVAN V, 1988, FRESEN Z ANAL CHEM, V329, P745
[9]  
LITTLEJOHN D, 1984, SPECTROCHIM ACTA B, V39, P321