SOURCES OF ERROR IN QUANTITATIVE CORONARY ANGIOGRAPHY

被引:20
作者
HERRINGTON, DM
SIEBES, M
WALFORD, GD
机构
[1] JOHNS HOPKINS UNIV,DEPT MED,DIV CARDIOL,BALTIMORE,MD 21218
[2] JET PROP LAB,PASADENA,CA 91109
来源
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS | 1993年 / 29卷 / 04期
关键词
QUANTITATIVE CORONARY ANGIOGRAPHY; CORONARY PHANTOMS; EDGE DETECTION;
D O I
10.1002/ccd.1810290416
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Many studies have reported the accuracy of quantitative coronary angiography (QCA) based on experiments using moderated-size phantoms imaged under unrealistic radiographic conditions. However, these observations may not be-generalizable to the setting of clinical angiography. To determine QCA accuracy in a realistic radiographic setting and evaluate the impact of the x-ray system line spread function, plexiglass phantoms were imaged inside and out of a human thorax. A realistic radiographic background was associated with a 38% increase in variability of results (P < 0.05). Low concentrations of contrast and large image intensifier input screens were associated with significantly larger errors and variability in results (p < 0.05). There was a systematic overestimation of diameter in the smallest phantom. A mathematical model of the x-ray line spread function was developed that explains the observed overestimation of the smallest phantom and provide a rational approach for correction of the line spread function for QCA. Many factors encountered in clinical coronary angiography such as nonuniform radiographic background, low concentrations of contrast, and small vessel diameters have a significant adverse impact on the accuracy and/or variability of gradient-based edge detection QCA systems. (C) 1993 Wiley-Liss, Inc.
引用
收藏
页码:314 / 321
页数:8
相关论文
共 22 条
[1]  
ALPERIN N, 1989, COMPUT CARDIOL, P153
[2]   ARTERIOGRAPHIC ASSESSMENT OF CORONARY ATHEROSCLEROSIS - REVIEW OF CURRENT METHODS, THEIR LIMITATIONS, AND CLINICAL-APPLICATIONS [J].
BROWN, BG ;
BOLSON, EL ;
DODGE, HT .
ARTERIOSCLEROSIS, 1982, 2 (01) :2-15
[3]   QUANTITATIVE CORONARY ARTERIOGRAPHY - ESTIMATION OF DIMENSIONS, HEMODYNAMIC RESISTANCE, AND ATHEROMA MASS OF CORONARY-ARTERY LESIONS USING ARTERIOGRAM AND DIGITAL COMPUTATION [J].
BROWN, BG ;
BOLSON, E ;
FRIMER, M ;
DODGE, HT .
CIRCULATION, 1977, 55 (02) :329-337
[4]  
HARRISON DG, 1984, CIRCULATION, V69, P111
[5]  
HERRINGTON DM, 1988, NEW DEV QUANTITATIVE, P153
[6]  
HERRINGTON DM, 1988, COMPUT CARDIOL, P351
[7]  
Johns HE, 1983, PHYS RADIOLOGY, V4th, P557
[8]  
KIRKEEIDE RL, 1982, COMPUT CARDIOL, P215
[9]   CORONARY-ARTERY QUANTITATION AND DATA MANAGEMENT-SYSTEM FOR PAIRED CINEANGIOGRAMS [J].
LEUNG, WH ;
SANDERS, W ;
ALDERMAN, EL .
CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1991, 24 (02) :121-134
[10]   AUTOMATED QUANTITATIVE CORONARY ARTERIOGRAPHY - MORPHOLOGICAL AND PHYSIOLOGICAL VALIDATION IN VIVO OF A RAPID DIGITAL ANGIOGRAPHIC METHOD [J].
MANCINI, GBJ ;
SIMON, SB ;
MCGILLEM, MJ ;
LEFREE, MT ;
FRIEDMAN, HZ ;
VOGEL, RA .
CIRCULATION, 1987, 75 (02) :452-460