COMPUTERIZED VOLUME MEASUREMENT OF BRAIN STRUCTURE

被引:67
作者
ASHTARI, M
ZITO, JL
GOLD, BI
LIEBERMAN, JA
BORENSTEIN, MT
HERMAN, PG
机构
[1] SUNY STONY BROOK,LAKEVILLE IMAGING CTR,STONY BROOK,NY 11794
[2] LONG ISL JEWISH MED CTR,DEPT PSYCHIAT,NEW HYDE PK,NY 11042
[3] EKTRON,APPL IMAGING,BEDFORD,MA
关键词
3-D gradient echo; Computer mensuration; Magnetic resonance imaging; Ventricular system; Volume measurement;
D O I
10.1097/00004424-199007000-00009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Morphometric analysis of brain structures recently has become a main focus of interest in studies of some neuropsychiatric diseases. Limitations in imaging and mensuration methodology that is available currently for quantitative measurement of anatomic structures have prompted the development of a computerized system to study brain morphometry. A menudriven semi-automated computer system has been developed to assess in vivo brain morphometry using three-dimensional (3-D) magnetic resonance (MR), gradient echo, contiguous images of the whole brain. Accuracy of the system was tested with phantoms creating white on black contrast to simulate the brain tissue surrounded by subarachnoid cerebrospinal fluid (CSF), and a second set of phantoms creating black on white contrast to simulate the ventricular system in the brain tissue. The first set of phantoms was composed of three waterfilled balloons (spherical, elliptical, and multiform) and a fresh postmortem brain. The second set of phantoms consisted of three rods of different diameters from a simple geometric plexiglass rod phantom and a life size cast of a human ventricular phantom. System accuracy was generally within 2.0% of the true volumes. System reliability was evaluated in three patient populations; 12 patients with Alzheimer’s disease, nine with schizophrenia and nine healthy controls agematched to the patients with Alzheimer’s disease. Two independent observers measured the ventricular systems of these patients. Reliability of the system was addressed by the correlation between the two sets of measurements. For the sample as a whole, and each of the subgroups, the correlation between the two observers was 0.99. This system compares favorably with other morphometric methods reported. © Lippincott-Raven Publishers.
引用
收藏
页码:798 / 805
页数:8
相关论文
共 19 条
  • [1] ANDREASEN N, 1986, ARCH GEN PSYCHIAT, V43, P136
  • [2] A FULLY-AUTOMATED COMPUTER-ASSISTED METHOD OF CT BRAIN-SCAN ANALYSIS FOR THE MEASUREMENT OF CEREBROSPINAL-FLUID SPACES AND BRAIN ABSORPTION DENSITY
    BALDY, RE
    BRINDLEY, GS
    EWUSIMENSAH, I
    JACOBSON, RR
    REVELEY, MA
    TURNER, SW
    LISHMAN, WA
    [J]. NEURORADIOLOGY, 1986, 28 (02) : 109 - 117
  • [3] DELISI LE, 1988, SCHIZOPHR RES, V1, P169
  • [4] EDARDS CH, 1973, ADV CALCULUS SEVERAL, P363
  • [5] VOLUMETRIC MEASUREMENTS OF THE CEREBROSPINAL-FLUID SPACES IN DEMENTED SUBJECTS AND CONTROLS
    GADO, M
    HUGHES, CP
    DANZIGER, W
    CHI, D
    JOST, G
    BERG, L
    [J]. RADIOLOGY, 1982, 144 (03) : 535 - 538
  • [6] COMPUTERIZED TOMOGRAPHY (EMI SCANNER) - COMPARISON WITH PNEUMOENCEPHALOGRAPHY AND VENTRICULOGRAPHY
    GAWLER, J
    DUBOULAY, GH
    BULL, JWD
    MARSHALL, J
    [J]. JOURNAL OF NEUROLOGY NEUROSURGERY AND PSYCHIATRY, 1976, 39 (03) : 203 - 211
  • [7] VENTRICULAR VOLUME AND COGNITIVE DEFICIT - A COMPUTED TOMOGRAPHIC STUDY
    GEORGE, AE
    DELEON, MJ
    ROSENBLOOM, S
    FERRIS, SH
    GENTES, C
    EMMERICH, M
    KRICHEFF, II
    [J]. RADIOLOGY, 1983, 149 (02) : 493 - 498
  • [8] AGE AND SEX DEPENDENCE OF SIZE OF NORMAL VENTRICLES ON COMPUTED TOMOGRAPHY
    HAUG, G
    [J]. NEURORADIOLOGY, 1977, 14 (04) : 201 - 204
  • [9] SEMI-AUTOMATED METHODS FOR QUANTITATING CSF VOLUME ON CRANIAL COMPUTED-TOMOGRAPHY
    JERNIGAN, TL
    ZATZ, LM
    NAESER, MA
    [J]. RADIOLOGY, 1979, 132 (02) : 463 - 466
  • [10] JOHNSTONE EC, 1976, LANCET, V2, P924